@ -77,27 +77,11 @@ below:
|
||||
Architecture Level
|
||||
==================
|
||||
|
||||
Fulfillment to FuSa Standards
|
||||
-----------------------------
|
||||
|
||||
The fulfillment matrix of error detection and error handling on architecture
|
||||
level to FuSa Standards [IEC_61508-7]_ in ACRN hypervisor is shown in
|
||||
:numref:`fulfillment_matrix_arch_level` below.
|
||||
|
||||
.. table:: Fulfillment to FuSa Standards on Architecture Level
|
||||
:align: center
|
||||
:widths: auto
|
||||
:name: fulfillment_matrix_arch_level
|
||||
|
||||
+-----------------------+---------------+----------+--------------------------------------+
|
||||
| Technique/Measure | Ref in | SIL3 | Company Solution |
|
||||
| | IEC 61508-7 | | |
|
||||
+=======================+===============+==========+======================================+
|
||||
| Failure assertion | C.3.3 | R | This technique will be used. |
|
||||
| programming | | | Plan to do range check in hypercalls |
|
||||
| | | | and HW capability checks. |
|
||||
+-----------------------+---------------+----------+--------------------------------------+
|
||||
Functional Safety Consideration
|
||||
-------------------------------
|
||||
|
||||
The hypervisor will do range check in hypercalls and HW capability checks
|
||||
according to Table A.2 of FuSa Standards [IEC_61508-3_2010]_ .
|
||||
|
||||
Error Handling Methods
|
||||
----------------------
|
||||
@ -243,28 +227,12 @@ Here is the sample codes for error checking before calling ``vcpu_from_vid``:
|
||||
Module Level
|
||||
============
|
||||
|
||||
Fulfillment to FuSa Standards
|
||||
-----------------------------
|
||||
|
||||
The fulfillment matrix of error detection and error handling on a module level
|
||||
to FuSa Standards [IEC_61508-7]_ in ACRN hypervisor is shown in
|
||||
:numref:`fulfillment_matrix_module_level` below.
|
||||
|
||||
.. table:: Fulfillment to FuSa Standards on Module Level
|
||||
:align: center
|
||||
:widths: auto
|
||||
:name: fulfillment_matrix_module_level
|
||||
|
||||
+-----------------------+---------------+----------+---------------------------------------------------+
|
||||
| Technique/Measure | Ref in | SIL3 | Company Solution |
|
||||
| | IEC 61508-7 | | |
|
||||
+=======================+===============+==========+===================================================+
|
||||
| Design and coding | C.2.6 | HR | This technique will be used for internal functions|
|
||||
| standards | Table B.1 | | of the hypervisor. Plan to use data verification, |
|
||||
| | | | with explicit specification of pre-conditions and |
|
||||
| | | | post-conditions for functions. |
|
||||
+-----------------------+---------------+----------+---------------------------------------------------+
|
||||
Functional Safety Consideration
|
||||
-------------------------------
|
||||
|
||||
Data verification, and explicit specification of pre-conditions and post-conditions
|
||||
are applied for internal functions of the hypervisor according to Table A.4 of
|
||||
FuSa Standards [IEC_61508-3_2010]_ .
|
||||
|
||||
Error Handling Methods
|
||||
----------------------
|
||||
@ -485,5 +453,4 @@ not NULL. If the VM called ``partition_mode_vpci_deinit`` twice, it may be NULL.
|
||||
References
|
||||
**********
|
||||
|
||||
.. [IEC_61508-7] IEC 61508-7:2010, Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures
|
||||
|
||||
.. [IEC_61508-3_2010] IEC 61508-3:2010, Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements
|
||||
|