doc: Grammatical updates to SR-IOV virt doc
Signed-off-by: Deb Taylor <deb.taylor@intel.com>
This commit is contained in:
parent
7b3c3c6bcf
commit
537f59f751
@ -4,174 +4,166 @@ SR-IOV Virtualization
|
|||||||
=====================
|
=====================
|
||||||
|
|
||||||
SR-IOV (Single Root Input/Output Virtualization) can isolate PCIe devices
|
SR-IOV (Single Root Input/Output Virtualization) can isolate PCIe devices
|
||||||
and make the devices to have good performance, close to bare-metal. The
|
to improve performance that is similar to bare-metal levels. SR-IOV consists
|
||||||
SR-IOV consists of two basic units, one is called PF(Physical Function)
|
of two basic units: PF (Physical Function), which supports SR-IOV PCIe
|
||||||
that supports SR-IOV PCIe extended capability and manages entire
|
extended capability and manages entire physical devices; and VF (Virtual
|
||||||
physical device, another is called VF (Virtual Function) and is a
|
Function), a "lightweight" PCIe function which is a passthrough device for
|
||||||
"lightweight" PCIe function which is meant to be given to a VM as a
|
VMs.
|
||||||
pass-through device.
|
|
||||||
|
|
||||||
For more details, please refer to PCI Express Base Specification Revision 4.0,
|
For details, refer to Chapter 9 of PCI-SIG's `PCI Express Base SpecificationRevision 4.0, Version 1.0 <https://pcisig.com/pci-express-architecture-configuration-space-test-specification-revision-40-version-10>`_.
|
||||||
Version 1.0 `PCI-SIG Specification <https://pcisig.com/specifications>` Chapter 9.
|
|
||||||
|
|
||||||
SR-IOV Architectural Overview
|
SR-IOV Architectural Overview
|
||||||
-----------------------------
|
-----------------------------
|
||||||
|
|
||||||
.. figure:: images/sriov-image1.png
|
.. figure:: images/sriov-image1.png
|
||||||
:align: center
|
:align: center
|
||||||
:width: 900px
|
|
||||||
:name: SR-IOV-architecture-overview
|
:name: SR-IOV-architecture-overview
|
||||||
|
|
||||||
SR-IOV Architectural Overview
|
SR-IOV Architectural Overview
|
||||||
|
|
||||||
- **SI** - System Image known as a VM.
|
- **SI** - A System Image known as a VM.
|
||||||
|
|
||||||
- **VI** - Virtualization Intermediary known as Hypervisor.
|
- **VI** - A Virtualization Intermediary known as a hypervisor.
|
||||||
|
|
||||||
- **SR-PCIM** - Single Root PCI Manager is a software entity for SR-IOV
|
- **SR-PCIM** - A Single Root PCI Manager; it is a software entity for
|
||||||
management.
|
SR-IOV management.
|
||||||
|
|
||||||
- **PF** - A PF is a PCIe Function that supports the SR-IOV capability
|
- **PF** - A PCIe Function that supports the SR-IOV capability
|
||||||
and is accessible to an SR-PCIM, a VI, or an SI.
|
and is accessible to an SR-PCIM, a VI, or an SI.
|
||||||
|
|
||||||
- **VF** - A VF is a “light-weight” PCIe Function that is directly
|
- **VF** - A “light-weight” PCIe Function that is directly accessible by an
|
||||||
accessible by an SI.
|
SI.
|
||||||
|
|
||||||
SR-IOV Extended Capability
|
SR-IOV Extended Capability
|
||||||
--------------------------
|
--------------------------
|
||||||
|
|
||||||
The SR-IOV Extended Capability defined here is a PCIe extended
|
The SR-IOV Extended Capability defined here is a PCIe extended
|
||||||
capability that must be implemented in each PF device that supports
|
capability that must be implemented in each PF device that supports the
|
||||||
SR-IOV feature. This Capability is used to describe and control a PF’s
|
SR-IOV feature. This capability is used to describe and control a PF’s
|
||||||
SR-IOV Capabilities.
|
SR-IOV Capabilities.
|
||||||
|
|
||||||
.. figure:: images/sriov-image2.png
|
.. figure:: images/sriov-image2.png
|
||||||
:align: center
|
:align: center
|
||||||
:width: 900px
|
|
||||||
:name: SR-IOV-extended-capability
|
:name: SR-IOV-extended-capability
|
||||||
|
|
||||||
SR-IOV Extended Capability
|
SR-IOV Extended Capability
|
||||||
|
|
||||||
- **PCIe Extended Capability ID** - 0010h.
|
- **PCIe Extended Capability ID** - 0010h.
|
||||||
|
|
||||||
- **SR-IOV Capabilities** - VF Migration Capable and ARI Capable.
|
- **SR-IOV Capabilities** - VF Migration-Capable and ARI-Capable.
|
||||||
|
|
||||||
- **SR-IOV Control** - Enable/Disable VFs, VF migration state query.
|
- **SR-IOV Control** - Enable/Disable VFs; VF migration state query.
|
||||||
|
|
||||||
- **SR-IOV Status** - VF Migration Status
|
- **SR-IOV Status** - VF Migration Status.
|
||||||
|
|
||||||
- **InitialVFs** - Indicates to SR-PCIM the number of VFs that are
|
- **InitialVFs** - Indicates to the SR-PCIM the number of VFs that are
|
||||||
initially associated with the PF
|
initially associated with the PF.
|
||||||
|
|
||||||
- **TotalVFs** - Indicates the maximum number of VFs that could be
|
- **TotalVFs** - Indicates the maximum number of VFs that can be
|
||||||
associated with the PF
|
associated with the PF.
|
||||||
|
|
||||||
- **NumVFs** - Controls the number of VFs that are visible. *NumVFs* <=
|
- **NumVFs** - Controls the number of VFs that are visible. *NumVFs* <=
|
||||||
*InitialVFs* = *TotalVFs*.
|
*InitialVFs* = *TotalVFs*.
|
||||||
|
|
||||||
- **Function Link Dependency** - The field is used to describe these
|
- **Function Link Dependency** - The field used to describe
|
||||||
dependencies between PFs. VF dependencies are the same as the
|
dependencies between PFs. VF dependencies are the same as the
|
||||||
dependencies of their associated PFs.
|
dependencies of their associated PFs.
|
||||||
|
|
||||||
- **First VF Offset** - It is a constant and defines the Routing ID
|
- **First VF Offset** - A constant that defines the Routing ID
|
||||||
offset of the first VF that is associated with the PF that contains
|
offset of the first VF that is associated with the PF that contains
|
||||||
this Capability structure
|
this Capability structure.
|
||||||
|
|
||||||
- **VF Stride** - It defines the Routing ID offset from one VF to the
|
- **VF Stride** - Defines the Routing ID offset from one VF to the
|
||||||
next one for all VFs associated with the PF that contains this
|
next one for all VFs associated with the PF that contains this
|
||||||
Capability structure.
|
Capability structure.
|
||||||
|
|
||||||
- **VF Device ID** - This field contains the Device ID that should be
|
- **VF Device ID** - The field that contains the Device ID that should be
|
||||||
presented for every VF to the SI.
|
presented for every VF to the SI.
|
||||||
|
|
||||||
- **Supported Page Sizes** - This field indicates the page sizes
|
- **Supported Page Sizes** - The field that indicates the page sizes
|
||||||
supported by the PF.
|
supported by the PF.
|
||||||
|
|
||||||
- **System Page Size** - This field defines the page size the system
|
- **System Page Size** - The field that defines the page size the system
|
||||||
will use to map the VFs’ memory addresses. Software must set the
|
will use to map the VFs’ memory addresses. Software must set the
|
||||||
value of the *System Page Size* to one of the page sizes set in the
|
value of the *System Page Size* to one of the page sizes set in the
|
||||||
*Supported Page Sizes* field
|
*Supported Page Sizes* field.
|
||||||
|
|
||||||
- **VF BARs** - These fields must define the VF’s Base Address
|
- **VF BARs** - Fields that must define the VF’s Base Address
|
||||||
Registers (BARs). These fields behave as normal PCI BARs.
|
Registers (BARs). These fields behave as normal PCI BARs.
|
||||||
|
|
||||||
- **VF Migration State Array Offset** - This register shall contain a
|
- **VF Migration State Array Offset** - Register that contains a
|
||||||
PF BAR relative pointer to the VF Migration State Array.
|
PF BAR relative pointer to the VF Migration State Array.
|
||||||
|
|
||||||
- **VF Migration State Array** – It is located using the VF Migration
|
- **VF Migration State Array** – Located using the VF Migration
|
||||||
State Array Offset register of the SR-IOV Capability block.
|
State Array Offset register of the SR-IOV Capability block.
|
||||||
|
|
||||||
For more details, please refer to *PCI Express Base Specification
|
For details, refer to the *PCI Express Base Specification Revision 4.0, Version 1.0 Chapter 9.3.3*.
|
||||||
Revision 4.0, Version 1.0 Chapter 9.3.3*
|
|
||||||
|
|
||||||
SR-IOV Architecture In ACRN
|
SR-IOV Architecture In ACRN
|
||||||
---------------------------
|
---------------------------
|
||||||
|
|
||||||
.. figure:: images/sriov-image3.png
|
.. figure:: images/sriov-image3.png
|
||||||
:align: center
|
:align: center
|
||||||
:width: 900px
|
|
||||||
:name: SR-IOV-architecure-in-acrn
|
:name: SR-IOV-architecure-in-acrn
|
||||||
|
|
||||||
SR-IOV Architectural in ACRN
|
SR-IOV Architectural in ACRN
|
||||||
|
|
||||||
1. Hypervisor detects SR-IOV capable PCIe device in physical PCI device
|
1. A hypervisor detects a SR-IOV capable PCIe device in the physical PCI
|
||||||
enumeration phase.
|
device enumeration phase.
|
||||||
|
|
||||||
2. Hypervisor intercepts the PF’s SR-IOV capability accessing to
|
2. The hypervisor intercepts the PF’s SR-IOV capability and accesses whether
|
||||||
enable/disable VF devices based on *VF\_ENABLE* state, and all
|
to enable/disable VF devices based on the *VF\_ENABLE* state. All
|
||||||
read/write requests for PF device are passthrough to PF physical
|
read/write requests for a PF device passthrough to the PF physical
|
||||||
device.
|
device.
|
||||||
|
|
||||||
3. Hypervisor waits for 100ms after *VF\_ENABLE* is set and initialize
|
3. The hypervisor waits for 100ms after *VF\_ENABLE* is set and initializes
|
||||||
VF devices. The differences between normal passthrough device and
|
VF devices. The differences between a normal passthrough device and
|
||||||
SR-IOV VF device are physical device detection, BARs and MSIx
|
SR-IOV VF device are physical device detection, BARs, and MSIx
|
||||||
initializations. Hypervisor uses *Subsystem Vendor ID* to detect
|
initialization. The hypervisor uses *Subsystem Vendor ID* to detect the
|
||||||
SR-IOV VF physical device instead *Vendor ID* since there is no valid
|
SR-IOV VF physical device instead of *Vendor ID* since no valid
|
||||||
*Vendor ID* for SR-IOV VF physical device, the VF BARs are
|
*Vendor ID* exists for the SR-IOV VF physical device. The VF BARs are
|
||||||
initialized by its associated PF’s SR-IOV capabilities not PCI
|
initialized by its associated PF’s SR-IOV capabilities, not PCI
|
||||||
standard BAR registers, MSIx mapping base address is also from PF’s
|
standard BAR registers. The MSIx mapping base address is also from the
|
||||||
SR-IOV capabilities not PCI standard BAR registers.
|
PF’s SR-IOV capabilities, not PCI standard BAR registers.
|
||||||
|
|
||||||
SR-IOV Passthrough VF Architecture In ACRN
|
SR-IOV Passthrough VF Architecture In ACRN
|
||||||
------------------------------------------
|
------------------------------------------
|
||||||
|
|
||||||
.. figure:: images/sriov-image4.png
|
.. figure:: images/sriov-image4.png
|
||||||
:align: center
|
:align: center
|
||||||
:width: 900px
|
|
||||||
:name: SR-IOV-vf-passthrough
|
:name: SR-IOV-vf-passthrough
|
||||||
|
|
||||||
SR-IOV VF Passthrough Architecture In ACRN
|
SR-IOV VF Passthrough Architecture In ACRN
|
||||||
|
|
||||||
1. The SR-IOV VF device needs to bind PCI-stud driver instead
|
1. The SR-IOV VF device needs to bind the PCI-stud driver instead of the
|
||||||
vendor-specific VF driver before passthrough the device.
|
vendor-specific VF driver before the device passthrough.
|
||||||
|
|
||||||
2. User configures ``acrn-dm`` boot parameter with passthrough SR-IOV VF
|
2. The user configures the ``acrn-dm`` boot parameter with the passthrough
|
||||||
device. When User VM starts, ``acrn-dm`` invokes a hypercall to set the
|
SR-IOV VF device. When the User VM starts, ``acrn-dm`` invokes a
|
||||||
*vdev-VF0* device in User VM.
|
hypercall to set the *vdev-VF0* device in the User VM.
|
||||||
|
|
||||||
3. Hypervisor emulates *Device ID/Vendor ID* and *Memory Space Enable
|
3. The hypervisor emulates *Device ID/Vendor ID* and *Memory Space Enable
|
||||||
(MSE*) in configuration space for an assigned SR-IOV VF device. The
|
(MSE)* in the configuration space for an assigned SR-IOV VF device. The
|
||||||
assigned VF *Device ID* comes from its associated PF’s capability,
|
assigned VF *Device ID* comes from its associated PF’s capability. The
|
||||||
*Vendor ID* is same with PF’s *Vendor ID* and *MSE* is always set
|
*Vendor ID* is the same as the PF’s *Vendor ID* and the *MSE* is always
|
||||||
when reading the SR-IOV VF device *CONTROL* register
|
set when reading the SR-IOV VF device's *CONTROL* register.
|
||||||
|
|
||||||
4. Vendor-specific VF driver in target VM probes the assigned SR-IOV VF
|
4. The vendor-specific VF driver in the target VM probes the assigned SR-IOV
|
||||||
device.
|
VF device.
|
||||||
|
|
||||||
SR-IOV Initialization Flow
|
SR-IOV Initialization Flow
|
||||||
--------------------------
|
--------------------------
|
||||||
|
|
||||||
.. figure:: images/sriov-image5.png
|
.. figure:: images/sriov-image5.png
|
||||||
:align: center
|
:align: center
|
||||||
:width: 900px
|
|
||||||
:name: SR-IOV-init-flow
|
:name: SR-IOV-init-flow
|
||||||
|
|
||||||
SR-IOV Initialization Flow
|
SR-IOV Initialization Flow
|
||||||
|
|
||||||
When a SR-IOV capable device is initialized, all access to the
|
When a SR-IOV capable device is initialized, all access to the
|
||||||
configuration space will pass through to the physical device directly.
|
configuration space will passthrough to the physical device directly.
|
||||||
Service VM can identify all capabilities of the device from SR-IOV extended
|
The Service VM can identify all capabilities of the device from the SR-IOV
|
||||||
capability then create sysfs node for SR-IOV management.
|
extended capability and then create an *sysfs* node for SR-IOV management.
|
||||||
|
|
||||||
SR-IOV VF Enable Flow
|
SR-IOV VF Enable Flow
|
||||||
---------------------
|
---------------------
|
||||||
@ -183,94 +175,87 @@ SR-IOV VF Enable Flow
|
|||||||
|
|
||||||
SR-IOV VF Enable Flow
|
SR-IOV VF Enable Flow
|
||||||
|
|
||||||
Application enables n VF devices via a SR-IOV PF device *sysfs* node.
|
The application enables n VF devices via a SR-IOV PF device *sysfs* node.
|
||||||
Hypervisor intercepts all SR-IOV capability accesses and check
|
The hypervisor intercepts all SR-IOV capability access and checks the
|
||||||
*VF\_ENABLE* state, if the *VF\_ENABLE* is set, hypervisor creates n
|
*VF\_ENABLE* state. If *VF\_ENABLE* is set, the hypervisor creates n
|
||||||
virtual devices after 100ms that VF physical devices have enough time to
|
virtual devices after 100ms so that VF physical devices have enough time to
|
||||||
be created. Service VM waits 100ms then only accesses the first VF device’s
|
be created. The Service VM waits 100ms and then only accesses the first VF
|
||||||
configuration space including *Class Code, Reversion ID, Subsystem
|
device’s configuration space including *Class Code, Reversion ID, Subsystem
|
||||||
Vendor ID, Subsystem ID,* Service VM uses the first VF device information to
|
Vendor ID, Subsystem ID*. The Service VM uses the first VF device
|
||||||
initialize subsequent VF devices.
|
information to initialize subsequent VF devices.
|
||||||
|
|
||||||
SR-IOV VF Disable Flow
|
SR-IOV VF Disable Flow
|
||||||
----------------------
|
----------------------
|
||||||
|
|
||||||
.. figure:: images/sriov-image7.png
|
.. figure:: images/sriov-image7.png
|
||||||
:align: center
|
:align: center
|
||||||
:width: 900px
|
|
||||||
:name: SR-IOV-disable-flow
|
:name: SR-IOV-disable-flow
|
||||||
|
|
||||||
SR-IOV VF Disable Flow
|
SR-IOV VF Disable Flow
|
||||||
|
|
||||||
Application disables SR-IOV VF devices by writing zero to SR-IOV PF
|
The application disables SR-IOV VF devices by writing zero to the SR-IOV PF
|
||||||
device *sysfs* node. Hypervisor intercepts all SR-IOV capability
|
device *sysfs* node. The hypervisor intercepts all SR-IOV capability
|
||||||
accesses and check *VF\_ENABLE* state, if *VF\_ENABLE* is clear,
|
accesses and checks the *VF\_ENABLE* state. If *VF\_ENABLE* is clear, the
|
||||||
hypervisor makes VF virtual devices invisible from Service VM that all accesses
|
hypervisor makes VF virtual devices invisible from the Service VM so that all
|
||||||
for VF will return 0xFFFFFFFF as an error, VF physical devices are
|
access to VF devices will return 0xFFFFFFFF as an error. The VF physical
|
||||||
removed within 1s of *VF\_ENABLE* is clear.
|
devices are removed within 1s of when *VF\_ENABLE* is clear.
|
||||||
|
|
||||||
SR-IOV VF Assignment Policy
|
SR-IOV VF Assignment Policy
|
||||||
---------------------------
|
---------------------------
|
||||||
|
|
||||||
.. figure:: images/sriov-image8.png
|
.. figure:: images/sriov-image8.png
|
||||||
:align: center
|
:align: center
|
||||||
:width: 900px
|
|
||||||
:name: SR-IOV-vf-assignment
|
:name: SR-IOV-vf-assignment
|
||||||
|
|
||||||
SR-IOV VF Assignment
|
SR-IOV VF Assignment
|
||||||
|
|
||||||
1. All SR-IOV PF devices are managed by Service VM.
|
1. All SR-IOV PF devices are managed by the Service VM.
|
||||||
|
|
||||||
2. Currently, SR-IOV PF can’t passthrough to User VM.
|
2. Currently, the SR-IOV PF cannot passthrough to the User VM.
|
||||||
|
|
||||||
3. All VFs can be passthrough to User VM, but we do not recommend
|
3. All VFs can passthrough to the User VM, but we do not recommend
|
||||||
passthrough to high privilege VMs, because PF device may impact
|
a passthrough to high privilege VMs because the PF device may impact
|
||||||
assigned VFs including functionality and stability.
|
the assigned VFs' functionality and stability.
|
||||||
|
|
||||||
SR-IOV Usage Guide In ACRN
|
SR-IOV Usage Guide In ACRN
|
||||||
--------------------------
|
--------------------------
|
||||||
|
|
||||||
We use Intel 82576 NIC as an example in here and only support LaaG
|
We use the Intel 82576 NIC as an example in the following instructions. We
|
||||||
(Linux as a Guest).
|
only support LaaG (Linux as a Guest).
|
||||||
|
|
||||||
1. Please ensure the 82576 VF driver is compiled into User VM Kernel
|
1. Ensure that the 82576 VF driver is compiled into the User VM Kernel
|
||||||
(Set *CONFIG\_IGBVF=y* in Kernel Config).
|
(set *CONFIG\_IGBVF=y* in the Kernel Config).
|
||||||
|
|
||||||
2. When the Service VM boot up, “\ *lspci -v*\ ” command can show Intel 82576
|
#. When the Service VM boots up, the ``\ *lspci -v*\`` command indicates
|
||||||
NIC devices have SR-IOV capability and their PF drivers are ``igb``.
|
that the Intel 82576 NIC devices have SR-IOV capability and their PF
|
||||||
|
drivers are ``igb``.
|
||||||
|
|
||||||
.. figure:: images/sriov-image9.png
|
.. figure:: images/sriov-image9.png
|
||||||
:align: center
|
:align: center
|
||||||
:width: 900px
|
:name: 82576-pf
|
||||||
:name: 82576-pf
|
|
||||||
|
|
||||||
82576 SR-IOV PF devices
|
82576 SR-IOV PF devices
|
||||||
|
|
||||||
1. Input "\ *echo n > /sys/class/net/enp109s0f0/device/sriov\_numvfs*\ "
|
#. Input the ``\ *echo n > /sys/class/net/enp109s0f0/device/sriov\_numvfs*\``
|
||||||
command in Service VM to enable n VF devices for the first PF
|
command in the Service VM to enable n VF devices for the first PF
|
||||||
device(\ *enp109s0f0)*. The number *n* can’t more than *TotalVFs*
|
device (\ *enp109s0f0)*. The number *n* can’t be more than *TotalVFs*
|
||||||
that comes from the return value of command
|
which comes from the return value of command ``cat /sys/class/net/enp109s0f0/device/sriov\_totalvfs``. Here we use *n = 2* as an example.
|
||||||
|
|
||||||
*“cat /sys/class/net/enp109s0f0/device/sriov\_totalvfs”*. Here we use
|
.. figure:: images/sriov-image10.png
|
||||||
*n = 2* for the example.
|
:align: center
|
||||||
|
:name: 82576-vf
|
||||||
|
|
||||||
.. figure:: images/sriov-image10.png
|
82576 SR-IOV VF devices
|
||||||
:align: center
|
|
||||||
:width: 900px
|
|
||||||
:name: 82576-vf
|
|
||||||
|
|
||||||
82576 SR-IOV VF devices
|
.. figure:: images/sriov-image11.png
|
||||||
|
:align: center
|
||||||
|
:name: 82576-vf-nic
|
||||||
|
|
||||||
.. figure:: images/sriov-image11.png
|
82576 SR-IOV VF NIC
|
||||||
:align: center
|
|
||||||
:width: 900px
|
|
||||||
:name: 82576-vf-nic
|
|
||||||
|
|
||||||
82576 SR-IOV VF NIC
|
#. Passthrough a SR-IOV VF device to guest.
|
||||||
|
|
||||||
1. Passthrough a SR-IOV VF device to guest
|
a. Unbind the igbvf driver in the Service VM.
|
||||||
|
|
||||||
a. Unbind igbvf driver in Service VM
|
|
||||||
|
|
||||||
i. *modprobe pci\_stub*
|
i. *modprobe pci\_stub*
|
||||||
|
|
||||||
@ -282,25 +267,25 @@ We use Intel 82576 NIC as an example in here and only support LaaG
|
|||||||
iv. *echo "0000:6d:10.0" >
|
iv. *echo "0000:6d:10.0" >
|
||||||
/sys/bus/pci/drivers/pci-stub/bind*
|
/sys/bus/pci/drivers/pci-stub/bind*
|
||||||
|
|
||||||
b. Add SR-IOV VF device parameter (“*-s X, passthru,6d/10/0*\ ”) in
|
b. Add the SR-IOV VF device parameter (“*-s X, passthru,6d/10/0*\ ”) in
|
||||||
launch User VM script
|
the launch User VM script
|
||||||
|
|
||||||
.. figure:: images/sriov-image12.png
|
.. figure:: images/sriov-image12.png
|
||||||
:align: center
|
:align: center
|
||||||
:width: 900px
|
:name: 82576-nic-passthru
|
||||||
:name: 82576-nic-passthru
|
|
||||||
|
|
||||||
Configure 82576 NIC as Passthrough Device
|
Configure 82576 NIC as a Passthrough Device
|
||||||
|
|
||||||
a. Boot User VM
|
c. Boot the User VM
|
||||||
|
|
||||||
SR-IOV Limitations In ACRN
|
SR-IOV Limitations In ACRN
|
||||||
--------------------------
|
--------------------------
|
||||||
|
|
||||||
1. The SR-IOV migration feature is not supported.
|
1. The SR-IOV migration feature is not supported.
|
||||||
|
|
||||||
2. If one SR-IOV PF device is detected during enumeration phase, but there is no
|
2. If one SR-IOV PF device is detected during the enumeration phase, but
|
||||||
enough room for its total VF devices, the PF device will be dropped. The platform
|
not enough room exists for its total VF devices, the PF device will be
|
||||||
uses *MAX_PCI_DEV_NUM* ACRN configuration to support the maximum number of PCI
|
dropped. The platform uses the *MAX_PCI_DEV_NUM* ACRN configuration to
|
||||||
devices, please make sure *MAX_PCI_DEV_NUM* is more than the number of all PCI
|
support the maximum number of PCI devices. Make sure *MAX_PCI_DEV_NUM* is
|
||||||
devices including total SR-IOV VF devices.
|
more than the number of all PCI devices, including the total SR-IOV VF
|
||||||
|
devices.
|
||||||
|
Loading…