mirror of
https://github.com/projectacrn/acrn-hypervisor.git
synced 2025-07-01 17:52:26 +00:00
dm:refine pm_vuart code
1) remove state machine 2) remove retry mechanism 3) pm thread only use to transmit data,not parse detailed message. v1-->v2: remove delay in pm_monitor_loop Tracked-On: #4446 Signed-off-by: Mingqiang Chi <mingqiang.chi@intel.com> Reviewed-by: Shuo A Liu <shuo.a.liu@intel.com> Reviewed-by: Minggui Cao <minggui.cao@intel.com> Reviewed-by: Yuhong Tao <yuhong.tao@intel.com> Acked-by: Wang, Yu1 <yu1.wang@intel.com>
This commit is contained in:
parent
f90100e382
commit
90b8d844d0
@ -30,9 +30,7 @@
|
|||||||
#include "log.h"
|
#include "log.h"
|
||||||
|
|
||||||
#define SHUTDOWN_CMD "shutdown"
|
#define SHUTDOWN_CMD "shutdown"
|
||||||
#define SHUTDOWN_CMD_ACK "acked"
|
|
||||||
#define CMD_LEN 16
|
#define CMD_LEN 16
|
||||||
#define RESEND_CMD_CNT 3
|
|
||||||
#define MAX_NODE_PATH 128
|
#define MAX_NODE_PATH 128
|
||||||
#define SOS_SOCKET_PORT 0x2000
|
#define SOS_SOCKET_PORT 0x2000
|
||||||
|
|
||||||
@ -47,19 +45,12 @@ enum node_type_t {
|
|||||||
MAX_NODE_CNT,
|
MAX_NODE_CNT,
|
||||||
};
|
};
|
||||||
|
|
||||||
/* Enumerated shutdown state machine */
|
|
||||||
enum shutdown_state {
|
|
||||||
SHUTDOWN_REQ_WAITING = 0, /* Can receive shutdown cmd in this state */
|
|
||||||
SHUTDOWN_ACK_WAITING, /* Wait acked message from UOS */
|
|
||||||
SHUTDOWN_REQ_FROM_SOS, /* Trigger shutdown by SOS */
|
|
||||||
SHUTDOWN_REQ_FROM_UOS, /* Trigger shutdown by UOS */
|
|
||||||
};
|
|
||||||
|
|
||||||
static uint8_t node_index = MAX_NODE_CNT;
|
static uint8_t node_index = MAX_NODE_CNT;
|
||||||
static char node_path[MAX_NODE_PATH];
|
static char node_path[MAX_NODE_PATH];
|
||||||
static int node_fd = -1;
|
static int node_fd = -1;
|
||||||
static enum shutdown_state pm_monitor_state = SHUTDOWN_REQ_WAITING;
|
static int socket_fd = -1;
|
||||||
static pthread_t pm_monitor_thread;
|
static pthread_t pm_monitor_thread;
|
||||||
|
static pthread_mutex_t pm_vuart_lock = PTHREAD_MUTEX_INITIALIZER;
|
||||||
|
|
||||||
static int vm_stop_handler(void *arg);
|
static int vm_stop_handler(void *arg);
|
||||||
static struct monitor_vm_ops vm_ops = {
|
static struct monitor_vm_ops vm_ops = {
|
||||||
@ -84,21 +75,13 @@ static int read_bytes(int fd, uint8_t *buffer, int buf_len)
|
|||||||
return count;
|
return count;
|
||||||
}
|
}
|
||||||
|
|
||||||
/*
|
int pm_setup_socket(void)
|
||||||
* acrn-dm receive shutdown command from UOS,
|
|
||||||
* it will call this api to send shutdown to life_mngr
|
|
||||||
* running on SOS
|
|
||||||
*/
|
|
||||||
int send_shutdown_to_lifemngr(void)
|
|
||||||
{
|
{
|
||||||
int rc;
|
|
||||||
char buffer[CMD_LEN];
|
|
||||||
int socket_fd;
|
|
||||||
struct sockaddr_in socket_addr;
|
struct sockaddr_in socket_addr;
|
||||||
|
|
||||||
socket_fd = socket(AF_INET, SOCK_STREAM, 0);
|
socket_fd = socket(AF_INET, SOCK_STREAM, 0);
|
||||||
if (socket_fd == -1) {
|
if (socket_fd == -1) {
|
||||||
pr_err("socket() error.\n");
|
pr_err("create a socket endpoint error\n");
|
||||||
return -1;
|
return -1;
|
||||||
}
|
}
|
||||||
|
|
||||||
@ -108,103 +91,53 @@ int send_shutdown_to_lifemngr(void)
|
|||||||
socket_addr.sin_addr.s_addr = inet_addr("127.0.0.1");
|
socket_addr.sin_addr.s_addr = inet_addr("127.0.0.1");
|
||||||
|
|
||||||
if (connect(socket_fd, (struct sockaddr *)&socket_addr, sizeof(socket_addr)) == -1) {
|
if (connect(socket_fd, (struct sockaddr *)&socket_addr, sizeof(socket_addr)) == -1) {
|
||||||
pr_err("connect() error.\n");
|
pr_err("initiate a connection on a socket error\n");
|
||||||
close(socket_fd);
|
close(socket_fd);
|
||||||
return -1;
|
return -1;
|
||||||
}
|
}
|
||||||
|
|
||||||
/* send shutdown command to lifecycle management process */
|
|
||||||
if (write(socket_fd, SHUTDOWN_CMD, sizeof(SHUTDOWN_CMD)) <= 0) {
|
|
||||||
pr_err("send shutdown cmd to lifecycle management process failed!\n");
|
|
||||||
close(socket_fd);
|
|
||||||
return -1;
|
|
||||||
}
|
|
||||||
|
|
||||||
/* wait the acked message from lifecycle management */
|
|
||||||
rc = read(socket_fd, (uint8_t *)buffer, sizeof(SHUTDOWN_CMD_ACK));
|
|
||||||
if ((rc > 0) && strncmp(buffer, SHUTDOWN_CMD_ACK, strlen(SHUTDOWN_CMD_ACK)) == 0) {
|
|
||||||
pr_info("received acked from lifecycle management process\n");
|
|
||||||
} else {
|
|
||||||
pr_err("received acked from lifecycle management failed!\n");
|
|
||||||
close(socket_fd);
|
|
||||||
return -1;
|
|
||||||
}
|
|
||||||
close(socket_fd);
|
|
||||||
return 0;
|
return 0;
|
||||||
}
|
}
|
||||||
|
|
||||||
/*
|
|
||||||
* this pm_monitor can do:
|
|
||||||
* --send shutdown request to UOS
|
|
||||||
* --receive acked message from UOS
|
|
||||||
* --receive shutdown request from UOS
|
|
||||||
*/
|
|
||||||
static void *pm_monitor_loop(void *arg)
|
static void *pm_monitor_loop(void *arg)
|
||||||
{
|
{
|
||||||
int rc;
|
int rc;
|
||||||
int retry = RESEND_CMD_CNT;
|
|
||||||
char buf[CMD_LEN];
|
char buf[CMD_LEN];
|
||||||
|
int max_fd;
|
||||||
|
fd_set read_fd;
|
||||||
|
|
||||||
while (1) {
|
if (pm_setup_socket() == -1) {
|
||||||
rc = read_bytes(node_fd, (uint8_t *)buf, CMD_LEN);
|
pr_err("create socket to connect life-cycle manager failed\n");
|
||||||
switch (pm_monitor_state) {
|
return NULL;
|
||||||
/* it can receive shutdown command from UOS for the following two states,
|
|
||||||
* it will change the state to SHUTDOWN_REQ_FROM_UOS if receive the shutdown
|
|
||||||
* command from UOS, this can prevent the follow-up shutdown command
|
|
||||||
* from UOS or SOS in this state.
|
|
||||||
* it will wait UOS poweroff itself and then send shutdown to
|
|
||||||
* life_mngr running on the SOS to shutdown system
|
|
||||||
*/
|
|
||||||
case SHUTDOWN_REQ_WAITING:
|
|
||||||
case SHUTDOWN_REQ_FROM_UOS:
|
|
||||||
if ((rc > 0) && (strncmp(SHUTDOWN_CMD, (const char *)buf, strlen(SHUTDOWN_CMD)) == 0)) {
|
|
||||||
pm_monitor_state = SHUTDOWN_REQ_FROM_UOS;
|
|
||||||
if (write(node_fd, SHUTDOWN_CMD_ACK, sizeof(SHUTDOWN_CMD_ACK))
|
|
||||||
!= sizeof(SHUTDOWN_CMD_ACK)) {
|
|
||||||
/* here no need to resend ack, it will resend shutdown cmd
|
|
||||||
* if uos can not receive acked message
|
|
||||||
*/
|
|
||||||
pr_err("send acked message to UOS failed!\n");
|
|
||||||
}
|
|
||||||
}
|
|
||||||
break;
|
|
||||||
|
|
||||||
/* Waiting acked message from UOS, this is triggered by SOS */
|
|
||||||
case SHUTDOWN_ACK_WAITING:
|
|
||||||
/* Once received the SHUTDOWN ACK from UOS, then wait UOS to set ACPI PM register to change
|
|
||||||
* VM to POWEROFF state
|
|
||||||
*/
|
|
||||||
if ((rc > 0) && (strncmp(SHUTDOWN_CMD_ACK, (const char *)buf, strlen(SHUTDOWN_CMD_ACK)) == 0)) {
|
|
||||||
pr_info("received acked message from uos\n");
|
|
||||||
} else {
|
|
||||||
/* it will try to resend shutdown cmd to UOS if there is no acked message from UOS */
|
|
||||||
if (retry > 0) {
|
|
||||||
if (write(node_fd, SHUTDOWN_CMD, sizeof(SHUTDOWN_CMD))
|
|
||||||
!= sizeof(SHUTDOWN_CMD)) {
|
|
||||||
pr_err("Try resend shutdown cmd failed cnt = %d\n", retry);
|
|
||||||
}
|
|
||||||
retry--;
|
|
||||||
} else {
|
|
||||||
/* If there is no acked message from UOS, just ignore the shutdown request
|
|
||||||
* from SOS, and the SOS can re-trigger shutdown flow,
|
|
||||||
* so it need restore the pm_monitor_state
|
|
||||||
*/
|
|
||||||
pr_err("Can not receive acked message from uos, have try %d times\r\n",
|
|
||||||
RESEND_CMD_CNT);
|
|
||||||
pm_monitor_state = SHUTDOWN_REQ_WAITING;
|
|
||||||
retry = RESEND_CMD_CNT;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
break;
|
|
||||||
|
|
||||||
default:
|
|
||||||
pr_err("Invalid pm_monitor_state(0x%x)\r\n", pm_monitor_state);
|
|
||||||
break;
|
|
||||||
}
|
|
||||||
sleep(1);
|
|
||||||
|
|
||||||
}
|
}
|
||||||
|
|
||||||
|
max_fd = (socket_fd > node_fd) ? (socket_fd + 1) : (node_fd + 1);
|
||||||
|
|
||||||
|
while (1) {
|
||||||
|
memset(buf, 0, CMD_LEN);
|
||||||
|
FD_ZERO(&read_fd);
|
||||||
|
FD_SET(socket_fd, &read_fd);
|
||||||
|
FD_SET(node_fd, &read_fd);
|
||||||
|
|
||||||
|
rc = select(max_fd, &read_fd, NULL, NULL, NULL);
|
||||||
|
if (rc > 0) {
|
||||||
|
if (FD_ISSET(node_fd, &read_fd)) {
|
||||||
|
rc = read_bytes(node_fd, (uint8_t *)buf, CMD_LEN);
|
||||||
|
pr_info("Received msg[%s] from UOS, rc=%d\r\n", buf, rc);
|
||||||
|
rc = write(socket_fd, buf, CMD_LEN);
|
||||||
|
} else if (FD_ISSET(socket_fd, &read_fd)) {
|
||||||
|
rc = read_bytes(socket_fd, (uint8_t *)buf, CMD_LEN);
|
||||||
|
pr_info("Received msg[%s] from life_mngr on SOS, rc=%d\r\n", buf, rc);
|
||||||
|
pthread_mutex_lock(&pm_vuart_lock);
|
||||||
|
rc = write(node_fd, buf, CMD_LEN);
|
||||||
|
pthread_mutex_unlock(&pm_vuart_lock);
|
||||||
|
}
|
||||||
|
|
||||||
|
if (rc != CMD_LEN) {
|
||||||
|
pr_err("%s: write error ret_val = 0x%x\r\n", rc);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
}
|
||||||
return NULL;
|
return NULL;
|
||||||
}
|
}
|
||||||
|
|
||||||
@ -319,23 +252,12 @@ void pm_by_vuart_init(struct vmctx *ctx)
|
|||||||
|
|
||||||
void pm_by_vuart_deinit(struct vmctx *ctx)
|
void pm_by_vuart_deinit(struct vmctx *ctx)
|
||||||
{
|
{
|
||||||
/* it indicates that acrn-dm has received shutdown command
|
|
||||||
* from UOS in this state, and it will send shutdown command
|
|
||||||
* to life_mngr running on SOS to shutdown system after UOS
|
|
||||||
* has poweroff itself.
|
|
||||||
*/
|
|
||||||
if (pm_monitor_state == SHUTDOWN_REQ_FROM_UOS) {
|
|
||||||
/* send shutdown command to life_mngr running on SOS */
|
|
||||||
if (send_shutdown_to_lifemngr() != 0) {
|
|
||||||
pr_err("send shutdown to life-management failed\r\n");
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
pthread_cancel(pm_monitor_thread);
|
pthread_cancel(pm_monitor_thread);
|
||||||
pthread_join(pm_monitor_thread, NULL);
|
pthread_join(pm_monitor_thread, NULL);
|
||||||
|
|
||||||
close(node_fd);
|
close(node_fd);
|
||||||
node_fd = -1;
|
node_fd = -1;
|
||||||
|
close(socket_fd);
|
||||||
|
socket_fd = -1;
|
||||||
}
|
}
|
||||||
|
|
||||||
/* called when acrn-dm receive stop command */
|
/* called when acrn-dm receive stop command */
|
||||||
@ -351,21 +273,13 @@ static int vm_stop_handler(void *arg)
|
|||||||
return -1;
|
return -1;
|
||||||
}
|
}
|
||||||
|
|
||||||
/* will ignore this shutdown command if it is shutdowning */
|
pthread_mutex_lock(&pm_vuart_lock);
|
||||||
if (pm_monitor_state != SHUTDOWN_REQ_WAITING) {
|
|
||||||
pr_err("can not shutdown in this state(0x%x),it is shutdowning\n", pm_monitor_state);
|
|
||||||
return -1;
|
|
||||||
}
|
|
||||||
|
|
||||||
pm_monitor_state = SHUTDOWN_REQ_FROM_SOS;
|
|
||||||
ret = write(node_fd, SHUTDOWN_CMD, sizeof(SHUTDOWN_CMD));
|
ret = write(node_fd, SHUTDOWN_CMD, sizeof(SHUTDOWN_CMD));
|
||||||
|
pthread_mutex_unlock(&pm_vuart_lock);
|
||||||
if (ret != sizeof(SHUTDOWN_CMD)) {
|
if (ret != sizeof(SHUTDOWN_CMD)) {
|
||||||
/* no need to resend shutdown here, will resend in pm_monitor thread */
|
/* no need to resend shutdown here, will resend in pm_monitor thread */
|
||||||
pr_err("send shutdown command to uos failed\r\n");
|
pr_err("send shutdown command to uos failed\r\n");
|
||||||
}
|
}
|
||||||
|
|
||||||
/* it will handle acked and resend shutdown cmd in pm_monitor thread */
|
|
||||||
pm_monitor_state = SHUTDOWN_ACK_WAITING;
|
|
||||||
|
|
||||||
return 0;
|
return 0;
|
||||||
}
|
}
|
||||||
|
Loading…
Reference in New Issue
Block a user