This patch is to change the vUART resource occupied by S5 function
between Service VM and guest VM to avoid the standard UART port
conflict when legacy UART passthrough to guest VM.
Tracked-On: #8622
Signed-off-by: YuanXin-Intel <xin.yuan@intel.com>
Reviewed-by: Junjie Mao <junjie.mao@intel.com>
Reviewed-by: Jian Jun Chen <jian.jun.chen@intel.com>
The offline tool use a utility libary and use "common" to named it, this
name conflict with some customer's local library, so we rename it to a
better and clear name.
Tracked-On: #6690
Signed-off-by: Chenli Wei <chenli.wei@intel.com>
Modified the copyright year range in code, and corrected "int32_tel"
into "Intel" in two "hypervisor/include/debug/profiling.h" and
"hypervisor/include/debug/profiling_internal.h".
Tracked-On: #7559
Signed-off-by: Ziheng Li <ziheng.li@intel.com>
There were some legacy logic of the current code, the PCI vUART index
in the launch script have not count the vUART of S5 and life_mngr_win
use the COM2 as default vUART.
This patch change the vUART index and irq to adapt above logic and all
of these legacy code will be refine next version.
Tracked-On: #6690
Signed-off-by: Chenli Wei <chenli.wei@intel.com>
The current code use COM1 or COM2 for LPC and there is an conflict with
S5 feature.
This patch filter these COM Ports and fix the above issue.
Tracked-On: #6690
Signed-off-by: Chenli Wei <chenli.wei@intel.com>
"S5" is one of the ACPI sleep states which means the function to shut
down the VMs.
On ACRN, the User VM must be shut down before powering off the Service
VM, so we need a vUART channel to communicate between the Service VM
and User VMs.
This patch adds a vUART channel for each User VM connect to Service VM
Tracked-On: #8782
Signed-off-by: Chenli Wei <chenli.wei@intel.com>
Reviewed-by: Junjie Mao <junjie.mao@intel.com>
Many of the license and Intel copyright headers include the "All rights
reserved" string. It is not relevant in the context of the BSD-3-Clause
license that the code is released under. This patch removes those strings
throughout the code (hypervisor, devicemodel and misc).
Tracked-On: #7254
Signed-off-by: Geoffroy Van Cutsem <geoffroy.vancutsem@intel.com>
As is recommended by UX/DX reviews, the per-VM console virtual UART is now
limited to the following choices:
- Disabled
- a COM port from COM1 to COM4
- PCI based
This patch converts the schema of scenario XMLs to integrate this
recommendation and add logic in the scenario upgrader to migrate data from
old scenario XMLs.
v1 -> v2:
* Update the static allocators and C source transformers according to the
new console vUART config item.
Tracked-On: #6690
Signed-off-by: Junjie Mao <junjie.mao@intel.com>
We have redesign the vuart and the UI for user, so the config tool
should change the schema and xform for the new xml, then change the
static_allocators to alloc irq and io_port for new connection.
This patch add a new vuart connection type and change the xforms to
adapter the new type.
Tracked-On: #6690
Reviewed-by: Junjie Mao <junjie.mao@intel.com>
Signed-off-by: Chenli Wei <chenli.wei@linux.intel.com>
The concept of guest_flags is hard to understand for users.
So turn guest_flags into several parameters in config tool
user interface, list as below:
GUEST_FLAG_LAPIC_PASSTHROUGH ---> lapic_passthrough
GUEST_FLAG_IO_COMPLETION_POLLING ---> io_completion_polling
GUEST_FLAG_VCAT_ENABLED ---> virtual_cat_support
GUEST_FLAG_SECURE_WORLD_ENABLED ---> secure_world_support
GUEST_FLAG_HIDE_MTRR ---> hide_mtrr_support
GUEST_FLAG_NVMX_ENABLED ---> nested_virtualization_support
GUEST_FLAG_SECURITY_VM ---> security_vm
GUEST_FLAG_RT ---> vm_type(RTVM)
GUEST_FLAG_TEE ---> vm_type(TEE_VM)
GUEST_FLAG_REE ---> vm_type(REE_VM)
In addition, HV global parameter NVMX_ENABLE is removed
from user interface, when config tool detects more than
one VM with nested_virtualization_support, NVMX_ENABLE is
assigned as 'y' automatically.
v1->v2:
*Rebase on the latest xml schema checking change
*Remove "all rights reserved" from the license header in guest_flags.py
v2->v3:
*Change the name of the new config items to CAPITAL_CASE style
*Combine guest flag policy to an XPATH in guest_flags.py
*Use count() to directly deduce NVMX_ENABLED in config_common.xsl and
update `boolean-by-key-value` to process 'true'
v3->v4:
*Change the name of the new config items to lower_case style
*Change guest_flag_node to allocation_vm_node in guest_flags.py
*Separate value case and key case for boolean-by-key-value
Tracked-On: #6690
Signed-off-by: hangliu1 <hang1.liu@linux.intel.com>
Reviewed-by: Junjie Mao <junjie.mao@intel.com>
This patch includes:
1.add load_order(PRE_LAUNCHED_VM/SERVICE_VM/POST_LAUNCHED_VM) parameter
2.change vm_type parameter to values as RTVM, STANDARD_VM, TEE, REE
TEE and REE are hide in UI.
3.deduce vm severity in vm_configuration from vm_type and load_order
This patch not includes:
change for scenario_config and functions called by scenario_config about checking
v2->v3:
*Refine template load_order
v1->v2:
*Change variable name from vm_type to load_order
*Change LoadOptionType to LoadOrderType
*Change VMOptionsType to VMType
*Add TEE_VM/REE_VM description
*Refine acrn:is-pre-launched-vm
Tracked-On: #6690
Signed-off-by: hangliu1 <hang1.liu@linux.intel.com>
Reviewed-by: Junjie Mao <junjie.mao@intel.com>
The interrupt pin descriptors in board XML follows the same notation as in
ACPI PRT (PCI Routing Table), i.e. either an integer or a pair of a device
object and an index.
However, the current static INTx allocator recognizes
integer-as-interrupt-line only, which will cause build-time failure if
the "device object + index" notation is used in physical DSDT to describe
PCI interrupt pin routing.
This patch refines the static allocator so that both notations can be
parsed properly. In case an interrupt line descriptor in the board XML
refers to an device object without an index, it is interpreted as the first
of the ACPI device object if it is an interrupt resource.
Tracked-On: #7058
Signed-off-by: Junjie Mao <junjie.mao@intel.com>
Acked-by: Anthony Xu <anthony.xu@intel.com>
Rename SOS_VM type to SERVICE_VM
rename UOS to User VM in XML description
rename uos_thread_pid to user_vm_thread_pid
rename devname_uos to devname_user_vm
rename uosid to user_vmid
rename UOS_ACK to USER_VM_ACK
rename SOS_VM_CONFIG_CPU_AFFINITY to SERVICE_VM_CONFIG_CPU_AFFINITY
rename SOS_COM to SERVICE_VM_COM
rename SOS_UART1_VALID_NUM" to SERVICE_VM_UART1_VALID_NUM
rename SOS_BOOTARGS_DIFF to SERVICE_VM_BOOTARGS_DIFF
rename uos to user_vm in launch script and xml
Tracked-On: #6744
Signed-off-by: Liu Long <long.liu@linux.intel.com>
Reviewed-by: Geoffroy Van Cutsem <geoffroy.vancutsem@intel.com>
Remove the restriction that SERIAL_CONSOLE needs to be ttys0, ttys1,
ttys2 or ttys3.
1. Lossen the restriction in xsd.
2. Rewrite the document.
3. Refine the intx.py. Refine the logic which take effect if the <irq>
is specified in "SOS_COM#_IRQ" for SOS VM's legacy vuart 0.
Tracked-On: #6610
Signed-off-by: Yang,Yu-chu <yu-chu.yang@intel.com>
Expand the capacity of legacy vuarts per VM. This change is applied to
manual scenario xml editing only.
A SOS VM can choose io port 0x3F8, 0x2F8, 0x3E8, 0x2E8 by selecting
SOS_COM1_BASE, SOS_COM2_BASE, SOS_COM3_BASE, SOS_COM4_BASE respectively.
Non SOS VM can choose io port 0x3F8, 0x2F8, 0x3E8, 0x2E8 by selecting
COM1_BASE, COM2_BASE, COM3_BASE, COM4_BASE respectively.
For any type of VM, selecting "CONFIG_COM_BASE" allows configuration tool
to pick an available io port from hardcoded list:
['0xA000', '0xA010', '0xA020', '0xA030', '0xA040', '0xA050', '0xA060', '0xA070']
A SOS VM can choose irq 4 by selecting SOS_COM1_IRQ and SOS_COM3_IRQ, and choose irq 3 by selecting SOS_COM2_IRQ and SOS_COM4_IRQ.
Non SOS VM can choose irq 4 by selecting COM1_IRQ and COM3_IRQ, and choose irq 3 by selecting COM2_IRQ and COM4_IRQ.
For SOS VM, selecting "CONFIG_COM_IRQ" allows configuration tool
to pick an available irq based on AVAILABLE_IRQ_INFO. For non SOS VM, it
will allocate an available irq from [1, 15].
Tracked-On: #6652
Signed-off-by: Yang,Yu-chu <yu-chu.yang@intel.com>
There could be multiple ways in the scenario configuration to specify that
no INTx allocation is explicitly allocation to a prelaunched VM:
* Do not have a `pt_intx` node at all.
* Have a `pt_intx` node with no text.
* Have a `pt_intx` node with a text that has nothing but whitespaces,
tabs and newlines.
The current implementation only supports the first way, and will cause
build-time failures when a scenario configuration uses the latter two. The
following changes are introduced by this patch to fix such errors.
* The INTx static allocator queries the text() of `pt_intx` nodes
directly to gracefully handle `pt_intx` nodes with no text.
* The XSLT of pt_intx.c clears all kinds of white spaces from the text of
`pt_intx` nodes before calculating the set of allocated INTx mappings.
Tracked-On: #6287
Signed-off-by: Junjie Mao <junjie.mao@intel.com>
This patch allocates interrupt lines among VMs according to the PCI devices
assigned to them.
v1 -> v2:
* Remove the usage of VMx_PT_INTX_NUM macro in vm_configuration.c; use the
concrete numbers directly.
* The static allocator will also complain if any interrupt line is allocated to
a VM with LAPIC_PASSTHROUGH.
v2 -> v3:
* Fix a minor coding style issue.
Tracked-On: #6287
Signed-off-by: Junjie Mao <junjie.mao@intel.com>
Create an intx.py which is a static allocator to allocate the irq
resources. The available irq list is based on the native irqs which
are in range [0, 15] and are not used by native os.
Tracked-On: #5980
Signed-off-by: Yang,Yu-chu <yu-chu.yang@intel.com>
Reviewed-by: Junjie Mao <junjie.mao@intel.com>