Change the generated config option documentation to use the DX-friendly names defined for the configurator UI (instead of the XML element name hierarchy previously used). Options are grouped by the top-level section (aka complex type) they belong to and then sorted alphabetically with these groups. Use badges to indicate where options can be found in the configurator UI and whether they're applicable to the Hypervisor or Pre/Post/Service VM. Add a custom css style for the config-option doc that puts the first paragraph of a glossary item on the same line as the glossary term so these badges look pretty. Added a acrn-custom.js patch that copies the alt text for images into a title property for images within the config-doc document. This provides tooltip text when hovering over the badges. Don't display options not visible in the configurator UI (elements with acrn:views=""). A missing acrn:views or acrn:applicable-vm means we look for an applicable value from an ancestor element. Add processing of a second xs:documentation element within an xs:annotation element. This second documentation element's content will be appended as a new paragraph to the first xs:documentation content in the generated documentation. Only the first xs:documentation element is used by the Configurator for its tooltips. Update documents that were referring to options by their XML names. Because we're now using a glossary to provide links to config options, we can't duplicate option names or glosary names anywhere in the doc set. Signed-off-by: David B. Kinder <david.b.kinder@intel.com>
89 lines
3.5 KiB
ReStructuredText
89 lines
3.5 KiB
ReStructuredText
.. _vcat_configuration:
|
|
|
|
Enable vCAT Configuration
|
|
#########################
|
|
|
|
vCAT is built on top of RDT, so to use vCAT we must first enable RDT.
|
|
For details on enabling RDT configuration on ACRN, see :ref:`rdt_configuration`.
|
|
For details on ACRN vCAT high-level design, see :ref:`hv_vcat`.
|
|
|
|
The vCAT feature is disabled by default in ACRN. You can enable vCAT via the UI,
|
|
the steps listed below serve as an FYI to show how those settings are translated
|
|
into XML in the scenario file:
|
|
|
|
#. Configure system level features:
|
|
|
|
- Edit ``hv.FEATURES.RDT.RDT_ENABLED`` to `y` to enable RDT
|
|
|
|
- Edit ``hv.FEATURES.RDT.CDP_ENABLED`` to `n` to disable CDP.
|
|
vCAT requires CDP to be disabled.
|
|
|
|
- Edit ``hv.FEATURES.RDT.VCAT_ENABLED`` to `y` to enable vCAT
|
|
|
|
.. code-block:: xml
|
|
:emphasize-lines: 3,4,5
|
|
|
|
<FEATURES>
|
|
<RDT>
|
|
<RDT_ENABLED>y</RDT_ENABLED>
|
|
<CDP_ENABLED>n</CDP_ENABLED>
|
|
<VCAT_ENABLED>y</VCAT_ENABLED>
|
|
<CLOS_MASK></CLOS_MASK>
|
|
</RDT>
|
|
</FEATURES>
|
|
|
|
#. In each Guest VM configuration:
|
|
|
|
- Edit ``vm.virtual_cat_support`` to 'y' to enable the vCAT feature on the VM.
|
|
|
|
- Edit ``vm.clos.vcpu_clos`` to assign COS IDs to the VM.
|
|
|
|
If ``GUEST_FLAG_VCAT_ENABLED`` is not specified for a VM (abbreviated as RDT VM):
|
|
``vcpu_clos`` is per CPU in a VM and it configures each CPU in a VM to a desired COS ID.
|
|
So the number of vcpu_closes is equal to the number of vCPUs assigned.
|
|
|
|
If ``GUEST_FLAG_VCAT_ENABLED`` is specified for a VM (abbreviated as vCAT VM):
|
|
``vcpu_clos`` is not per CPU anymore; instead, it specifies a list of physical COS IDs (minimum 2)
|
|
that are assigned to a vCAT VM. The number of vcpu_closes is not necessarily equal to
|
|
the number of vCPUs assigned, but may be not only greater than the number of vCPUs assigned but
|
|
less than this number. Each vcpu_clos will be mapped to a virtual COS ID, the first vcpu_clos
|
|
is mapped to virtual COS ID 0 and the second is mapped to virtual COS ID 1, etc.
|
|
|
|
.. code-block:: xml
|
|
:emphasize-lines: 3,10,11,12,13
|
|
|
|
<vm id="1">
|
|
<guest_flags>
|
|
<guest_flag>GUEST_FLAG_VCAT_ENABLED</guest_flag>
|
|
</guest_flags>
|
|
<cpu_affinity>
|
|
<pcpu_id>1</pcpu_id>
|
|
<pcpu_id>2</pcpu_id>
|
|
</cpu_affinity>
|
|
<clos>
|
|
<vcpu_clos>2</vcpu_clos>
|
|
<vcpu_clos>4</vcpu_clos>
|
|
<vcpu_clos>5</vcpu_clos>
|
|
<vcpu_clos>7</vcpu_clos>
|
|
</clos>
|
|
</vm>
|
|
|
|
.. note::
|
|
CLOS_MASK defined in scenario file is a capacity bitmask (CBM) starting
|
|
at bit position low (the lowest assigned physical cache way) and ending at position
|
|
high (the highest assigned physical cache way, inclusive). As CBM only allows
|
|
contiguous '1' combinations, so CLOS_MASK essentially is the maximum CBM that covers
|
|
all the physical cache ways assigned to a vCAT VM.
|
|
|
|
The config tool imposes oversight to prevent any problems with invalid configuration data for vCAT VMs:
|
|
|
|
* For a vCAT VM, its vcpu_closes cannot be set to 0, COS ID 0 is reserved to be used only by hypervisor
|
|
|
|
* There should not be any COS ID overlap between a vCAT VM and any other VMs. e.g. the vCAT VM has exclusive use of the assigned COS IDs
|
|
|
|
* For a vCAT VM, each vcpu_clos must be less than L2/L3 COS_MAX
|
|
|
|
* For a vCAT VM, its vcpu_closes cannot contain duplicate values
|
|
|
|
#. Follow instructions in :ref:`gsg` and build with this XML configuration.
|