Transcode, edit, and upload HLD 0.7 section 3.10 (PM in hypervisor), 3.11 (Console, shell, vUART), 3.12 (Hypercall/VHM upcall), and 3.13 (Compile-time config) Also scan/replace UTF-8 punctuation missed in previous PRs. Add anchor targets in referenced docs. Tracked-on: #1648 Signed-off-by: David B. Kinder <david.b.kinder@intel.com>
50 lines
1.7 KiB
ReStructuredText
50 lines
1.7 KiB
ReStructuredText
.. _pm_hld:
|
|
|
|
Power Management
|
|
################
|
|
|
|
System PM module
|
|
****************
|
|
|
|
The PM module in the hypervisor does three things:
|
|
|
|
- When all UOSes enter low power state, VM management will notify the SOS
|
|
lifecycle service and trigger the SOS to enter a low-power state.
|
|
SOS follows its own standard low-power state entry process and
|
|
writes the ACPI control register to put SOS into low-power state.
|
|
Hypervisor traps the ACPI control register writing and
|
|
emulates SOS low-power state entry.
|
|
|
|
- Once SOS low-power emulation is done, Hypervisor handles its
|
|
own low-power state transition
|
|
|
|
- Once system resumes from low-power mode, the hypervisor handles its
|
|
own resume and emulates SOS resume too.
|
|
|
|
It is assumed that SOS does not trigger any power state transition until
|
|
the VM manager of ACRN notifies it that all UOSes are inactive and SOS
|
|
offlines all its virtual APs.
|
|
|
|
:numref:`pm-low-power-transition` shows the SOS/Hypervisor low-power
|
|
state transition process. SOS triggers power state transition by
|
|
writing ACPI control register on its virtual BSP (which is pinned to the
|
|
physical BSP). The hypervisor then does the following in sequence before
|
|
it writes to the physical ACPI control register to trigger physical
|
|
power state transition:
|
|
|
|
- Pauses SOS.
|
|
- Offlines all physical APs.
|
|
- Save the context of console, ioapic of SOS, I/O MMU, lapic of SOS,
|
|
virtual BSP.
|
|
- Save the context of physical BSP.
|
|
|
|
When exiting from low-power mode, the hypervisor does similar steps in
|
|
reverse order to restore contexts, start APs and resume SOS. SOS is
|
|
responsible for starting its own virtual APs as well as UOSes.
|
|
|
|
.. figure:: images/pm-image24-105.png
|
|
:align: center
|
|
:name: pm-low-power-transition
|
|
|
|
SOS/Hypervisor low power state transition process
|