Files
acrn-hypervisor/misc/acrn-config/xmls/config-xmls/apl-mrb/hybrid.xml
Wei Liu db909edda5 acrn-config: refine the data type for member of class
Unify the data type for scenario item.

1. Unified the scenario item, the type modified from list to dictionary.
2. remove some unused function.
3. add 'pci_dev_num'/'pci_devs' to hybrid xml for future support.

Tracked-On: #3798
Signed-off-by: Wei Liu <weix.w.liu@intel.com>
Acked-by: Victor Sun <victor.sun@intel.com>
2019-10-12 16:22:27 +08:00

112 lines
7.9 KiB
XML

<acrn-config board="apl-mrb" scenario="hybrid">
<vm id="0">
<load_order desc="Specify the VM by its load order: PRE_LAUNCHED_VM, SOS_VM or POST_LAUNCHED_VM." readonly="true">PRE_LAUNCHED_VM</load_order>
<name desc="Specify the VM name which will be shown in hypervisor console command: vm_list.">ACRN PRE-LAUNCHED VM0</name>
<uuid configurable="0" desc="vm uuid">fc836901-8685-4bc0-8b71-6e31dc36fa47</uuid>
<guest_flags desc="Select all applicable flags for the VM" multiselect="true">
<guest_flag>GUEST_FLAG_HIGHEST_SEVERITY</guest_flag>
</guest_flags>
<pcpu_ids desc="Assign physical CPU IDs to the VM" multiselect="true">
<pcpu_id>3</pcpu_id>
</pcpu_ids>
<clos desc="Class of Service for Cache Allocation Technology. Please refer SDM 17.19.2 for details and use with caution.">0</clos>
<epc_section desc="epc section">
<base desc="SGX EPC section base, must be page aligned">0</base>
<size desc="SGX EPC section size in Bytes, must be page aligned">0</size>
</epc_section>
<memory>
<start_hpa desc="The start physical address in host for the VM">0x100000000</start_hpa>
<size desc="The memory size in Bytes for the VM">0x20000000</size>
</memory>
<os_config>
<name desc="Specify the OS name of VM, currently it is not referenced by hypervisor code.">Zephyr</name>
<kern_type desc="Specify the kernel image type so that hypervisor could load it correctly. Currently support KERNEL_BZIMAGE and KERNEL_ZEPHYR.">KERNEL_ZEPHYR</kern_type>
<kern_mod desc="The tag for kernel image which act as multiboot module, it must exactly match the module tag in GRUB multiboot cmdline.">Zephyr_RawImage</kern_mod>
<bootargs desc="Specify kernel boot arguments"></bootargs>
<kern_load_addr desc="The loading address in host memory for the VM kernel">0x100000</kern_load_addr>
<kern_entry_addr desc="The entry address in host memory for the VM kernel">0x100000</kern_entry_addr>
</os_config>
<vuart id="0">
<type configurable="0" desc="vCOM1 type">VUART_LEGACY_PIO</type>
<base desc="vUART0 (A.K.A COM1) enabling switch. Enable by exposing its base address, disable by returning invalid base address." readonly="true">COM1_BASE</base>
<irq configurable="0" desc="vCOM1 irq">COM1_IRQ</irq>
</vuart>
<vuart id="1">
<type configurable="0" desc="vCOM2 type">VUART_LEGACY_PIO</type>
<base desc="vUART1 (A.K.A COM2) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">COM2_BASE</base>
<irq configurable="0" desc="vCOM2 irq">COM2_IRQ</irq>
<target_vm_id desc="COM2 is used for VM communications. When it is enabled, please specify which target VM that current VM connect to.">1</target_vm_id>
<target_uart_id configurable="0" desc="target vUART ID that vCOM2 connect to">1</target_uart_id>
</vuart>
<pci_dev_num configurable="0" desc="pci devices number"></pci_dev_num>
<pci_devs configurable="0" desc="pci devices list"></pci_devs>
</vm>
<vm id="1">
<load_order desc="Specify the VM by its load order: PRE_LAUNCHED_VM, SOS_VM or POST_LAUNCHED_VM." readonly="true">SOS_VM</load_order>
<name desc="Specify the VM name which will be shown in hypervisor console command: vm_list.">ACRN SOS VM</name>
<uuid configurable="0" desc="vm uuid">dbbbd434-7a57-4216-a12c-2201f1ab0240</uuid>
<guest_flags desc="Select all applicable flags for the VM" multiselect="true">
<guest_flag>0</guest_flag>
</guest_flags>
<clos desc="Class of Service for Cache Allocation Technology. Please refer SDM 17.19.2 for details and use with caution.">0</clos>
<memory>
<start_hpa configurable="0" desc="The start physical address in host for the VM">0</start_hpa>
<size configurable="0" desc="The memory size in Bytes for the VM">CONFIG_SOS_RAM_SIZE</size>
</memory>
<os_config>
<name desc="Specify the OS name of VM, currently it is not referenced by hypervisor code.">ACRN Service OS</name>
<kern_type desc="Specify the kernel image type so that hypervisor could load it correctly. Currently support KERNEL_BZIMAGE and KERNEL_ZEPHYR.">KERNEL_BZIMAGE</kern_type>
<kern_mod desc="The tag for kernel image which act as multiboot module, it must exactly match the module tag in GRUB multiboot cmdline.">Linux_bzImage</kern_mod>
<bootargs configurable="0" desc="Specify kernel boot arguments">SOS_VM_BOOTARGS</bootargs>
</os_config>
<vuart id="0">
<type configurable="0" desc="vCOM1 type">VUART_LEGACY_PIO</type>
<base desc="vUART0 (A.K.A COM1) enabling switch. Enable by exposing its base address, disable by returning invalid base address." readonly="true">SOS_COM1_BASE</base>
<irq configurable="0" desc="vCOM1 irq">SOS_COM1_IRQ</irq>
</vuart>
<vuart id="1">
<type configurable="0" desc="vCOM2 type">VUART_LEGACY_PIO</type>
<base desc="vUART1 (A.K.A COM2) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">SOS_COM2_BASE</base>
<irq configurable="0" desc="vCOM2 irq">SOS_COM2_IRQ</irq>
<target_vm_id desc="COM2 is used for VM communications. When it is enabled, please specify which target VM that current VM connect to.">0</target_vm_id>
<target_uart_id configurable="0" desc="target vUART ID that vCOM2 connect to">1</target_uart_id>
</vuart>
<pci_dev_num configurable="0" desc="pci devices number">SOS_EMULATED_PCI_DEV_NUM</pci_dev_num>
<pci_devs configurable="0" desc="pci devices list">sos_pci_devs</pci_devs>
<board_private>
<rootfs desc="rootfs for Linux kernel">/dev/mmcblk1p1</rootfs>
<console desc="ttyS console for Linux kernel">/dev/ttyS2</console>
<bootargs desc="Specify kernel boot arguments">
rw rootwait console=tty0 consoleblank=0 no_timer_check quiet loglevel=3
i915.nuclear_pageflip=1 i915.avail_planes_per_pipe=0x01010F i915.domain_plane_owners=0x011111110000 i915.enable_gvt=1
hvlog=2M@0x6de00000 memmap=0x600000$0x6da00000 ramoops.mem_address=0x6da00000 ramoops.mem_size=0x400000 ramoops.console_size=0x200000
reboot_panic=p,w module_blacklist=dwc3_pci i915.enable_initial_modeset=1 i915.enable_guc=0x02 video=DP-1:d video=DP-2:d cma=64M@0- panic_print=0x1f
</bootargs>
</board_private>
</vm>
<vm id="2">
<load_order desc="Specify the VM by its load order: PRE_LAUNCHED_VM, SOS_VM or POST_LAUNCHED_VM." readonly="true">POST_LAUNCHED_VM</load_order>
<uuid configurable="0" desc="vm uuid">d2795438-25d6-11e8-864e-cb7a18b34643</uuid>
<guest_flags desc="Select all applicable flags for the VM" multiselect="true">
<guest_flag>0</guest_flag>
</guest_flags>
<clos desc="Class of Service for Cache Allocation Technology. Please refer SDM 17.19.2 for details and use with caution.">0</clos>
<epc_section desc="epc section">
<base desc="SGX EPC section base, must be page aligned">0</base>
<size desc="SGX EPC section size in Bytes, must be page aligned">0</size>
</epc_section>
<vuart id="0">
<type configurable="0" desc="vCOM1 type">VUART_LEGACY_PIO</type>
<base desc="vUART0 (A.K.A COM1) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">COM1_BASE</base>
<irq configurable="0" desc="vCOM1 irq">COM1_IRQ</irq>
</vuart>
<vuart id="1">
<type configurable="0" desc="vCOM2 type">VUART_LEGACY_PIO</type>
<base desc="vUART1 (A.K.A COM2) enabling switch. Enable by exposing its base address, disable by returning invalid base address.">INVALID_COM_BASE</base>
<irq configurable="0" desc="vCOM2 irq">COM2_IRQ</irq>
<target_vm_id desc="COM2 is used for VM communications. When it is enabled, please specify which target VM that current VM connect to.">0</target_vm_id>
<target_uart_id configurable="0" desc="target vUART ID that vCOM2 connect to">0</target_uart_id>
</vuart>
</vm>
</acrn-config>