doc: Add documentation for the virtualization reference architecture
Fixes: #4041 Signed-off-by: Zvonko Kaiser <zkaiser@nvidia.com>
This commit is contained in:
parent
ff8bfdfe3b
commit
d035955ef5
@ -13,6 +13,7 @@ Kata Containers design documents:
|
||||
- [Design for Kata Containers `Lazyload` ability with `nydus`](kata-nydus-design.md)
|
||||
- [Design for direct-assigned volume](direct-blk-device-assignment.md)
|
||||
- [Design for core-scheduling](core-scheduling.md)
|
||||
- [Virtualization Reference Architecture](kata-vra.md)
|
||||
---
|
||||
|
||||
- [Design proposals](proposals)
|
||||
|
434
docs/design/kata-vra.md
Normal file
434
docs/design/kata-vra.md
Normal file
@ -0,0 +1,434 @@
|
||||
# Virtualization Reference Architecture
|
||||
|
||||
## Subject to Change | © 2022 by NVIDIA Corporation. All rights reserved. | For test and development only_
|
||||
|
||||
Before digging deeper into the virtualization reference architecture, let's
|
||||
first look at the various GPUDirect use cases in the following table. We’re
|
||||
distinguishing between two top-tier use cases where the devices are (1)
|
||||
passthrough and (2) virtualized, where a VM gets assigned a virtual function
|
||||
(VF) and not the physical function (PF). A combination of PF and VF would also
|
||||
be possible.
|
||||
|
||||
| Device #1 (passthrough) | Device #2 (passthrough) | P2P Compatibility and Mode |
|
||||
| ------------------------- | ----------------------- | -------------------------------------------- |
|
||||
| GPU PF | GPU PF | GPUDirect P2P |
|
||||
| GPU PF | NIC PF | GPUDirect RDMA |
|
||||
| MIG-slice | MIG-slice | _No GPUDirect P2P_ |
|
||||
| MIG-slice | NIC PF | GPUDirect RDMA |
|
||||
| **PDevice #1 (virtualized)** | **Device #2 (virtualized)** | **P2P Compatibility and Mode** |
|
||||
| Time-slice vGPU VF | Time-slice vGPU VF | _No GPUDirect P2P but NVLINK P2P available_ |
|
||||
| Time-slice vGPU VF | NIC VF | GPUDirect RDMA |
|
||||
| MIG-slice vGPU | MIG-slice vGPU | _No GPUDirect P2P_ |
|
||||
| MIG-slice vGPU | NIC VF | GPUDirect RDMA |
|
||||
|
||||
In a virtualized environment we have several distinct features that may prevent
|
||||
Peer-to-peer (P2P) communication of two endpoints in a PCI Express topology. The
|
||||
IOMMU translates IO virtual addresses (IOVA) to physical addresses (PA). Each
|
||||
device behind an IOMMU has its own IOVA memory space, usually, no two devices
|
||||
share the same IOVA memory space but it’s up to the hypervisor or OS how it
|
||||
chooses to map devices to IOVA spaces. Any PCI Express DMA transactions will
|
||||
use IOVAs, which the IOMMU must translate. By default, all the traffic is routed
|
||||
to the root complex and not issued directly to the peer device.
|
||||
|
||||
An IOMMU can be used to isolate and protect devices even if virtualization is
|
||||
not used; since devices can only access memory regions that are mapped for it, a
|
||||
DMA from one device to another is not possible. DPDK uses the IOMMU to have
|
||||
better isolation between devices, another benefit is that IOVA space can be
|
||||
represented as a contiguous memory even if the PA space is heavily scattered.
|
||||
|
||||
In the case of virtualization, the IOMMU is responsible for isolating the device
|
||||
and memory between VMs for safe device assignment without compromising the host
|
||||
and other guest OSes. Without an IOMMU, any device can access the entire system
|
||||
and perform DMA transactions _anywhere_.
|
||||
|
||||
The second feature is ACS (Access Control Services), which controls which
|
||||
devices are allowed to communicate with one another and thus avoids improper
|
||||
routing of packets irrespectively of whether IOMMU is enabled or not.
|
||||
|
||||
When IOMMU is enabled, ACS is normally configured to force all PCI Express DMA
|
||||
to go through the root complex so IOMMU can translate it, impacting performance
|
||||
between peers with higher latency and reduced bandwidth.
|
||||
|
||||
A way to avoid the performance hit is to enable Address Translation Services
|
||||
(ATS). ATS-capable endpoints can prefetch IOVA -> PA translations from the IOMMU
|
||||
and then perform DMA transactions directly to another endpoint. Hypervisors
|
||||
enable this by enabling ATS in such endpoints, configuring ACS to enable Direct
|
||||
Translated P2P, and configuring the IOMMU to allow Address Translation requests.
|
||||
|
||||
Another important factor is that the NVIDIA driver stack will use the PCI
|
||||
Express topology of the system it is running on to determine whether the
|
||||
hardware is capable of supporting P2P. The driver stack qualifies specific
|
||||
chipsets, and PCI Express switches for use with GPUDirect P2P. In virtual
|
||||
environments, the PCI Express topology is flattened and obfuscated to present a
|
||||
uniform environment to the software inside the VM, which breaks the GPUDirect
|
||||
P2P use case.
|
||||
|
||||
On a bare metal machine, the driver stack groups GPUs into cliques that can
|
||||
perform GPUDirect P2P communication, excluding peer mappings where P2P
|
||||
communication is not possible, prominently if GPUs are attached to multiple CPU
|
||||
sockets.
|
||||
|
||||
CPUs and local memory banks are referred to as NUMA nodes. In a two-socket
|
||||
server, each of the CPUs has a local memory bank for a total of two NUMA nodes.
|
||||
Some servers provide the ability to configure additional NUMA nodes per CPU,
|
||||
which means a CPU socket can have two NUMA nodes (some servers support four
|
||||
NUMA nodes per socket) with local memory banks and L3 NUMA domains for improved
|
||||
performance.
|
||||
|
||||
One of the current solutions is that the hypervisor provides additional topology
|
||||
information that the driver stack can pick up and enable GPUDirect P2P between
|
||||
GPUs, even if the virtualized environment does not directly expose it. The PCI
|
||||
Express virtual P2P approval capability structure in the PCI configuration space
|
||||
is entirely emulated by the hypervisor of passthrough GPU devices.
|
||||
|
||||
A clique ID is provided where GPUs with the same clique ID belong to a group of
|
||||
GPUs capable of P2P communication
|
||||
|
||||
On vSphere, Azure, and other CPSs, the hypervisor lays down a `topologies.xml`
|
||||
which NCCL can pick up and deduce the right P2P level[^1]. NCCL is leveraging
|
||||
Infiniband (IB) and/or Unified Communication X (UCX) for communication, and
|
||||
GPUDirect P2P and GPUDirect RDMA should just work in this case. The only culprit
|
||||
is that software or applications that do not use the XML file to deduce the
|
||||
topology will fail and not enable GPUDirect ( [`nccl-p2p-level`](https://docs.nvidia.com/deeplearning/nccl/user-guide/docs/env.html#nccl-p2p-level) )
|
||||
|
||||
## Hypervisor PCI Express Topology
|
||||
|
||||
To enable every part of the accelerator stack, we propose a virtualized
|
||||
reference architecture to enable GPUDirect P2P and GPUDirect RDMA for any
|
||||
hypervisor. The idea is split into two parts to enable the right PCI Express
|
||||
topology. The first part builds upon extending the PCI Express virtual P2P
|
||||
approval capability structure to every device that wants to do P2P in some way
|
||||
and groups devices by clique ID. The other part involves replicating a subset of
|
||||
the host topology so that applications running in the VM do not need to read
|
||||
additional information and enable the P2P capability like in the bare-metal use
|
||||
case described above. The driver stack can then deduce automatically if the
|
||||
topology presented in the VM is capable of P2P communication.
|
||||
|
||||
We will work with the following host topology for the following sections. It is
|
||||
a system with two converged DPUs, each having an `A100X` GPU and two `ConnectX-6`
|
||||
network ports connected to the downstream ports of a PCI Express switch.
|
||||
|
||||
```sh
|
||||
+-00.0-[d8-df]----00.0-[d9-df]--+-00.0-[da-db]--+-00.0 Mellanox Tech MT42822 BlueField-2 integrated ConnectX-6 Dx network
|
||||
| +-00.1 Mellanox Tech MT42822 BlueField-2 integrated ConnectX-6 Dx network
|
||||
| \-00.2 Mellanox Tech MT42822 BlueField-2 SoC Management Interface
|
||||
\-01.0-[dc-df]----00.0-[dd-df]----08.0-[de-df]----00.0 NVIDIA Corporation GA100 [A100X]
|
||||
|
||||
+-00.0-[3b-42]----00.0-[3c-42]--+-00.0-[3d-3e]--+-00.0 Mellanox Tech MT42822 BlueField-2 integrated ConnectX-6 Dx network
|
||||
| +-00.1 Mellanox Tech MT42822 BlueField-2 integrated ConnectX-6 Dx network
|
||||
| \-00.2 Mellanox Tech MT42822 BlueField-2 SoC Management Interface
|
||||
\-01.0-[3f-42]----00.0-[40-42]----08.0-[41-42]----00.0 NVIDIA Corporation GA100 [A100X]
|
||||
```
|
||||
|
||||
The green path highlighted above is the optimal and preferred path for
|
||||
efficient P2P communication.
|
||||
|
||||
## PCI Express Virtual P2P Approval Capability
|
||||
|
||||
Most of the time, the PCI Express topology is flattened and obfuscated to ensure
|
||||
easy migration of the VM image between different physical hardware topologies.
|
||||
In Kata, we can configure the hypervisor to use PCI Express root ports to
|
||||
hotplug the VFIO devices one is passing through. A user can select how many PCI
|
||||
Express root ports to allocate depending on how many devices are passed through.
|
||||
A recent addition to Kata will detect the right amount of PCI Express devices
|
||||
that need hotplugging and bail out if the number of root ports is insufficient.
|
||||
In Kata, we do not automatically increase the number of root ports, we want the
|
||||
user to be in full control of the topology.
|
||||
|
||||
```toml
|
||||
# /etc/kata-containers/configuration.toml
|
||||
|
||||
# VFIO devices are hotplugged on a bridge by default.
|
||||
# Enable hot-plugging on the root bus. This may be required for devices with
|
||||
# a large PCI bar, as this is a current limitation with hot-plugging on
|
||||
# a bridge.
|
||||
# Default “bridge-port”
|
||||
hotplug_vfio = "root-port"
|
||||
|
||||
# Before hot plugging a PCIe device, you need to add a pcie_root_port device.
|
||||
# Use this parameter when using some large PCI bar devices, such as NVIDIA GPU
|
||||
# The value means the number of pcie_root_port
|
||||
# This value is valid when hotplug_vfio_on_root_bus is true and machine_type is "q35"
|
||||
# Default 0
|
||||
pcie_root_port = 8
|
||||
```
|
||||
|
||||
VFIO devices are hotplugged on a PCIe-PCI bridge by default. Hotplug of PCI
|
||||
Express devices is only supported on PCI Express root or downstream ports. With
|
||||
this configuration set, if we start up a Kata container, we can inspect our
|
||||
topology and see the allocated PCI Express root ports and the hotplugged
|
||||
devices.
|
||||
|
||||
```sh
|
||||
$ lspci -tv
|
||||
-[0000:00]-+-00.0 Intel Corporation 82G33/G31/P35/P31 Express DRAM Controller
|
||||
+-01.0 Red Hat, Inc. Virtio console
|
||||
+-02.0 Red Hat, Inc. Virtio SCSI
|
||||
+-03.0 Red Hat, Inc. Virtio RNG
|
||||
+-04.0-[01]----00.0 Mellanox Technologies MT42822 BlueField-2 integrated ConnectX-6
|
||||
+-05.0-[02]----00.0 Mellanox Technologies MT42822 BlueField-2 integrated ConnectX-6
|
||||
+-06.0-[03]----00.0 NVIDIA Corporation Device 20b8
|
||||
+-07.0-[04]----00.0 NVIDIA Corporation Device 20b8
|
||||
+-08.0-[05]--
|
||||
+-09.0-[06]--
|
||||
+-0a.0-[07]--
|
||||
+-0b.0-[08]--
|
||||
+-0c.0 Red Hat, Inc. Virtio socket
|
||||
+-0d.0 Red Hat, Inc. Virtio file system
|
||||
+-1f.0 Intel Corporation 82801IB (ICH9) LPC Interface Controller
|
||||
+-1f.2 Intel Corporation 82801IR/IO/IH (ICH9R/DO/DH) 6 port SATA Controller
|
||||
\-1f.3 Intel Corporation 82801I (ICH9 Family) SMBus Controller
|
||||
```
|
||||
|
||||
For devices with huge BARs (Base Address Registers) like the GPU (we need to
|
||||
configure the PCI Express root port properly and allocate enough memory for
|
||||
mapping), we have added a heuristic to Kata to deduce the right settings. Hence,
|
||||
the BARs can be mapped correctly. This functionality is added to
|
||||
[`nvidia/go-nvlib1](https://gitlab.com/nvidia/cloud-native/go-nvlib) which is part
|
||||
of Kata now.
|
||||
|
||||
```sh
|
||||
$ sudo dmesg | grep BAR
|
||||
[ 0.179960] pci 0000:00:04.0: BAR 7: assigned [io 0x1000-0x1fff]
|
||||
[ 0.179962] pci 0000:00:05.0: BAR 7: assigned [io 0x2000-0x2fff]
|
||||
[ 0.179963] pci 0000:00:06.0: BAR 7: assigned [io 0x3000-0x3fff]
|
||||
[ 0.179964] pci 0000:00:07.0: BAR 7: assigned [io 0x4000-0x4fff]
|
||||
[ 0.179966] pci 0000:00:08.0: BAR 7: assigned [io 0x5000-0x5fff]
|
||||
[ 0.179967] pci 0000:00:09.0: BAR 7: assigned [io 0x6000-0x6fff]
|
||||
[ 0.179968] pci 0000:00:0a.0: BAR 7: assigned [io 0x7000-0x7fff]
|
||||
[ 0.179969] pci 0000:00:0b.0: BAR 7: assigned [io 0x8000-0x8fff]
|
||||
[ 2.115912] pci 0000:01:00.0: BAR 0: assigned [mem 0x13000000000-0x13001ffffff 64bit pref]
|
||||
[ 2.116203] pci 0000:01:00.0: BAR 2: assigned [mem 0x13002000000-0x130027fffff 64bit pref]
|
||||
[ 2.683132] pci 0000:02:00.0: BAR 0: assigned [mem 0x12000000000-0x12001ffffff 64bit pref]
|
||||
[ 2.683419] pci 0000:02:00.0: BAR 2: assigned [mem 0x12002000000-0x120027fffff 64bit pref]
|
||||
[ 2.959155] pci 0000:03:00.0: BAR 1: assigned [mem 0x11000000000-0x117ffffffff 64bit pref]
|
||||
[ 2.959345] pci 0000:03:00.0: BAR 3: assigned [mem 0x11800000000-0x11801ffffff 64bit pref]
|
||||
[ 2.959523] pci 0000:03:00.0: BAR 0: assigned [mem 0xf9000000-0xf9ffffff]
|
||||
[ 2.966119] pci 0000:04:00.0: BAR 1: assigned [mem 0x10000000000-0x107ffffffff 64bit pref]
|
||||
[ 2.966295] pci 0000:04:00.0: BAR 3: assigned [mem 0x10800000000-0x10801ffffff 64bit pref]
|
||||
[ 2.966472] pci 0000:04:00.0: BAR 0: assigned [mem 0xf7000000-0xf7ffffff]
|
||||
```
|
||||
|
||||
The NVIDIA driver stack in this case would refuse to do P2P communication since
|
||||
(1) the topology is not what it expects, (2) we do not have a qualified
|
||||
chipset. Since our P2P devices are not connected to a PCI Express switch port,
|
||||
we need to provide additional information to support the P2P functionality. One
|
||||
way of providing such meta information would be to annotate the container; most
|
||||
of the settings in Kata's configuration file can be overridden via annotations,
|
||||
but this limits the flexibility, and a user would need to update all the
|
||||
containers that he wants to run with Kata. The goal is to make such things as
|
||||
transparent as possible, so we also introduced
|
||||
[CDI](https://github.com/container-orchestrated-devices/container-device-interface)
|
||||
(Container Device Interface) to Kata. CDI is a[
|
||||
specification](https://github.com/container-orchestrated-devices/container-device-interface/blob/master/SPEC.md)
|
||||
for container runtimes to support third-party devices.
|
||||
|
||||
As written before, we can provide a clique ID for the devices that belong
|
||||
together and are capable of doing P2P. This information is provided to the
|
||||
hypervisor, which will set up things in the VM accordingly. Let's suppose the
|
||||
user wanted to do GPUDirect RDMA with the first GPU and the NIC that reside on
|
||||
the same DPU, one could provide the specification telling the hypervisor that
|
||||
they belong to the same clique.
|
||||
|
||||
```yaml
|
||||
# /etc/cdi/nvidia.yaml
|
||||
cdiVersion: 0.4.0
|
||||
kind: nvidia.com/gpu
|
||||
devices:
|
||||
- name: gpu0
|
||||
annotations:
|
||||
bdf: “41:00.0”
|
||||
clique-id: “0”
|
||||
containerEdits:
|
||||
deviceNodes:
|
||||
- path: “/dev/vfio/71"
|
||||
|
||||
# /etc/cdi/mellanox.yaml
|
||||
cdiVersion: 0.4.0
|
||||
kind: mellanox.com/nic
|
||||
devices:
|
||||
- name: nic0
|
||||
annotations:
|
||||
bdf: “3d:00.0”
|
||||
clique-id: “0”
|
||||
attach-pci: “true”
|
||||
containerEdits:
|
||||
deviceNodes:
|
||||
- path: "/dev/vfio/66"
|
||||
```
|
||||
|
||||
Since this setting is bound to the device and not the container we do not need
|
||||
to alter the container just allocate the right resource and GPUDirect RDMA would
|
||||
be set up correctly. Rather than exposing them separately, an idea would be to
|
||||
expose a GPUDirect RDMA device via NFD (Node Feature Discovery) that combines
|
||||
both of them; this way, we could make sure that the right pair is allocated and
|
||||
used more on Kubernetes deployment in the next section.
|
||||
|
||||
The GPU driver stack is leveraging the PCI Express virtual P2P approval
|
||||
capability, but the NIC stack does not use this now. One of the action items is
|
||||
to enable MOFED to read the P2P approval capability and enable ATS and ACS
|
||||
settings as described above.
|
||||
|
||||
This way, we could enable GPUDirect P2P and GPUDirect RDMA on any topology
|
||||
presented to the VM application. It is the responsibility of the administrator
|
||||
or infrastructure engineer to provide the right information either via
|
||||
annotations or a CDI specification.
|
||||
|
||||
## Host Topology Replication
|
||||
|
||||
The other way to represent the PCI Express topology in the VM is to replicate a
|
||||
subset of the topology needed to support the P2P use case inside the VM. Similar
|
||||
to the configuration for the root ports, we can easily configure the usage of
|
||||
PCI Express switch ports to hotplug the devices.
|
||||
|
||||
```toml
|
||||
# /etc/kata-containers/configuration.toml
|
||||
|
||||
# VFIO devices are hotplugged on a bridge by default.
|
||||
# Enable hot plugging on the root bus. This may be required for devices with
|
||||
# a large PCI bar, as this is a current limitation with hot plugging on
|
||||
# a bridge.
|
||||
# Default “bridge-port”
|
||||
hotplug_vfio = "switch-port"
|
||||
|
||||
# Before hot plugging a PCIe device, you need to add a pcie_root_port device.
|
||||
# Use this parameter when using some large PCI bar devices, such as Nvidia GPU
|
||||
# The value means the number of pcie_root_port
|
||||
# This value is valid when hotplug_vfio_on_root_bus is true and machine_type is "q35"
|
||||
# Default 0
|
||||
pcie_switch_port = 8
|
||||
```
|
||||
|
||||
Each device that is passed through is attached to a PCI Express downstream port
|
||||
as illustrated below. We can even replicate the host’s two DPUs topologies with
|
||||
added metadata through the CDI. Most of the time, a container only needs one
|
||||
pair of GPU and NIC for GPUDirect RDMA. This is more of a showcase of what we
|
||||
can do with the power of Kata and CDI. One could even think of adding groups of
|
||||
devices that support P2P, even from different CPU sockets or NUMA nodes, into
|
||||
one container; indeed, the first group is NUMA node 0 (red), and the second
|
||||
group is NUMA node 1 (green). Since they are grouped correctly, P2P would be
|
||||
enabled naturally inside a group, aka clique ID.
|
||||
|
||||
```sh
|
||||
$ lspci -tv
|
||||
-[0000:00]-+-00.0 Intel Corporation 82G33/G31/P35/P31 Express DRAM Controller
|
||||
+-01.0 Red Hat, Inc. Virtio console
|
||||
+-02.0 Red Hat, Inc. Virtio SCSI
|
||||
+-03.0 Red Hat, Inc. Virtio RNG
|
||||
+-04.0-[01-04]----00.0-[02-04]--+-00.0-[03]----00.0 NVIDIA Corporation Device 20b8
|
||||
| \-01.0-[04]----00.0 Mellanox Tech MT42822 BlueField-2 integrated ConnectX-6 Dx
|
||||
+-05.0-[05-08]----00.0-[06-08]--+-00.0-[07]----00.0 Mellanox Tech MT42822 BlueField-2 integrated ConnectX-6 Dx
|
||||
| \-01.0-[08]----00.0 NVIDIA Corporation Device 20b8
|
||||
+-06.0 Red Hat, Inc. Virtio socket
|
||||
+-07.0 Red Hat, Inc. Virtio file system
|
||||
+-1f.0 Intel Corporation 82801IB (ICH9) LPC Interface Controller
|
||||
+-1f.2 Intel Corporation 82801IR/IO/IH (ICH9R/DO/DH) 6 port SATA Controller [AHCI mode]
|
||||
\-1f.3 Intel Corporation 82801I (ICH9 Family) SMBus Controller
|
||||
\-1f.3 Intel Corporation 82801I (ICH9 Family) SMBus Controller
|
||||
```
|
||||
|
||||
The configuration of using either the root port or switch port can be applied on
|
||||
a per Container or Pod basis, meaning we can switch PCI Express topologies on
|
||||
each run of an application.
|
||||
|
||||
## Hypervisor Resource Limits
|
||||
|
||||
Every hypervisor will have resource limits in terms of how many PCI Express root
|
||||
ports, switch ports, or bridge ports can be created, especially with devices
|
||||
that need to reserve a 4K IO range per PCI specification. Each instance of root
|
||||
or switch port will consume 4K IO of very limited capacity, 64k is the maximum.
|
||||
|
||||
Simple math brings us to the conclusion that we can have a maximum of 16 PCI
|
||||
Express root ports or 16 PCI Express switch ports in QEMU if devices with IO
|
||||
BARs are used in the PCI Express hierarchy.
|
||||
|
||||
Additionally, one can have 32 slots on the PCI root bus and a maximum of 256
|
||||
slots for the complete PCI(e) topology.
|
||||
|
||||
Per default, QEMU will attach a multi-function device in the last slot on the
|
||||
PCI root bus,
|
||||
|
||||
```sh
|
||||
+-1f.0 Intel Corporation 82801IB (ICH9) LPC Interface Controller
|
||||
+-1f.2 Intel Corporation 82801IR/IO/IH (ICH9R/DO/DH) 6 port SATA Controller [AHCI mode]
|
||||
\-1f.3 Intel Corporation 82801I (ICH9 Family) SMBus Controller
|
||||
```
|
||||
|
||||
Kata will additionally add `virtio-xxx-pci` devices consuming (5 slots) plus a
|
||||
PCIe-PCI-bridge (1 slot) and a DRAM controller (1 slot), meaning per default, we
|
||||
have already eight slots used. This leaves us 24 slots for adding other devices
|
||||
to the root bus.
|
||||
|
||||
The problem that arises here is one use-case from a customer that uses recent
|
||||
RTX GPUs with Kata. The user wanted to pass through eight of these GPUs into one
|
||||
container and ran into issues. The problem is that those cards often consist of
|
||||
four individual device nodes: GPU, Audio, and two USB controller devices (some
|
||||
cards have a USB-C output).
|
||||
|
||||
These devices are grouped into one IOMMU group. Since one needs to pass through
|
||||
the complete IOMMU group into the VM, we need to allocate 32 PCI Express root
|
||||
ports or 32 PCI Express switch ports, which is technically impossible due to the
|
||||
resource limits outlined above. Since all the devices appear as PCI Express
|
||||
devices, we need to hotplug those into a root or switch port.
|
||||
|
||||
The solution to this problem is leveraging CDI. For each device, add the
|
||||
information if it is going to be hotplugged as a PCI Express or PCI device,
|
||||
which results in either using a PCI Express root/switch port or an ordinary PCI
|
||||
bridge. PCI bridges are not affected by the limited IO range. This way, the GPU
|
||||
is attached as a PCI Express device to a root/switch port and the other three
|
||||
PCI devices to a PCI bridge, leaving enough resources to create the needed PCI
|
||||
Express root/switch ports. For example, we’re going to attach the GPUs to a PCI
|
||||
Express root port and the NICs to a PCI bridge.
|
||||
|
||||
```jsonld
|
||||
# /etc/cdi/mellanox.json
|
||||
cdiVersion: 0.4.0
|
||||
kind: mellanox.com/nic
|
||||
devices:
|
||||
- name: nic0
|
||||
annotations:
|
||||
bdf: “3d:00.0”
|
||||
clique-id: “0”
|
||||
attach-pci: “true”
|
||||
containerEdits:
|
||||
deviceNodes:
|
||||
- path: "/dev/vfio/66"
|
||||
- name: nic1
|
||||
annotations:
|
||||
bdf: “3d:00.1”
|
||||
clique-id: “1”
|
||||
attach-pci: “true”
|
||||
containerEdits:
|
||||
deviceNodes:
|
||||
- path: "/dev/vfio/67”
|
||||
```
|
||||
|
||||
The configuration is set to use eight root ports for the GPUs and attach the
|
||||
NICs to a PCI bridge which is connected to a PCI Express-PCI bridge which is the
|
||||
preferred way of introducing a PCI topology in a PCI Express machine.
|
||||
|
||||
```sh
|
||||
$ lspci -tv
|
||||
-[0000:00]-+-00.0 Intel Corporation 82G33/G31/P35/P31 Express DRAM Controller
|
||||
+-01.0 Red Hat, Inc. Virtio console
|
||||
+-02.0 Red Hat, Inc. Virtio SCSI
|
||||
+-03.0 Red Hat, Inc. Virtio RNG
|
||||
+-04.0-[01]----00.0 NVIDIA Corporation Device 20b8
|
||||
+-05.0-[02]----00.0 NVIDIA Corporation Device 20b8
|
||||
+-06.0-[03]--
|
||||
+-07.0-[04]--
|
||||
+-08.0-[05]--
|
||||
+-09.0-[06]--
|
||||
+-0a.0-[07]--
|
||||
+-0b.0-[08]--
|
||||
+-0c.0-[09-0a]----00.0-[0a]--+-00.0 Mellanox Tech MT42822 BlueField-2 ConnectX-6
|
||||
| \-01.0 Mellanox Tech MT42822 BlueField-2 ConnectX-6
|
||||
+-0d.0 Red Hat, Inc. Virtio socket
|
||||
+-0e.0 Red Hat, Inc. Virtio file system
|
||||
+-1f.0 Intel Corporation 82801IB (ICH9) LPC Interface Controller
|
||||
+-1f.2 Intel Corporation 82801IR/IO/IH (ICH9R/DO/DH) 6 port SATA Controller
|
||||
\-1f.3 Intel Corporation 82801I (ICH9 Family) SMBus Controller
|
||||
```
|
||||
|
||||
The PCI devices will consume a slot of which we have 256 in the PCI(e) topology
|
||||
and leave scarce resources for the needed PCI Express devices.
|