Files
kata-containers/cli/kata-check_amd64_test.go
Julio Montes e84a9a70b0 cli: Add initial cli implementation.
- Add kata-runtime
- Add unit test
- Add Makefile to build cli

Fixes: #33

Signed-off-by: Julio Montes <julio.montes@intel.com>
Signed-off-by: James O. D. Hunt <james.o.hunt@intel.com>
Signed-off-by: Jose Carlos Venegas Munoz <jose.carlos.venegas.munoz@intel.com>
2018-03-15 12:10:52 -06:00

467 lines
10 KiB
Go

// Copyright (c) 2018 Intel Corporation
//
// Licensed under the Apache License, Version 2.0 (the "License");
// you may not use this file except in compliance with the License.
// You may obtain a copy of the License at
//
// http://www.apache.org/licenses/LICENSE-2.0
//
// Unless required by applicable law or agreed to in writing, software
// distributed under the License is distributed on an "AS IS" BASIS,
// WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
// See the License for the specific language governing permissions and
// limitations under the License.
package main
import (
"bytes"
"io/ioutil"
"os"
"path"
"path/filepath"
"regexp"
"strings"
"testing"
"github.com/sirupsen/logrus"
"github.com/stretchr/testify/assert"
"github.com/urfave/cli"
)
func setupCheckHostIsVMContainerCapable(assert *assert.Assertions, cpuInfoFile string, cpuData []testCPUData, moduleData []testModuleData) {
createModules(assert, cpuInfoFile, moduleData)
// all the modules files have now been created, so deal with the
// cpuinfo data.
for _, d := range cpuData {
err := makeCPUInfoFile(cpuInfoFile, d.vendorID, d.flags)
assert.NoError(err)
details := vmContainerCapableDetails{
cpuInfoFile: cpuInfoFile,
requiredCPUFlags: archRequiredCPUFlags,
requiredCPUAttribs: archRequiredCPUAttribs,
requiredKernelModules: archRequiredKernelModules,
}
err = hostIsVMContainerCapable(details)
if d.expectError {
assert.Error(err)
} else {
assert.NoError(err)
}
}
}
func TestCCCheckCLIFunction(t *testing.T) {
assert := assert.New(t)
dir, err := ioutil.TempDir("", "")
if err != nil {
t.Fatal(err)
}
defer os.RemoveAll(dir)
savedSysModuleDir := sysModuleDir
savedProcCPUInfo := procCPUInfo
cpuInfoFile := filepath.Join(dir, "cpuinfo")
// XXX: override
sysModuleDir = filepath.Join(dir, "sys/module")
procCPUInfo = cpuInfoFile
defer func() {
sysModuleDir = savedSysModuleDir
procCPUInfo = savedProcCPUInfo
}()
err = os.MkdirAll(sysModuleDir, testDirMode)
if err != nil {
t.Fatal(err)
}
cpuData := []testCPUData{
{"GenuineIntel", "lm vmx sse4_1", false},
}
moduleData := []testModuleData{
{filepath.Join(sysModuleDir, "kvm_intel/parameters/unrestricted_guest"), false, "Y"},
{filepath.Join(sysModuleDir, "kvm_intel/parameters/nested"), false, "Y"},
}
devNull, err := os.OpenFile(os.DevNull, os.O_WRONLY, 0666)
assert.NoError(err)
defer devNull.Close()
savedLogOutput := kataLog.Logger.Out
// discard normal output
kataLog.Logger.Out = devNull
defer func() {
kataLog.Logger.Out = savedLogOutput
}()
setupCheckHostIsVMContainerCapable(assert, cpuInfoFile, cpuData, moduleData)
app := cli.NewApp()
ctx := cli.NewContext(app, nil, nil)
app.Name = "foo"
// create buffer to save logger output
buf := &bytes.Buffer{}
// capture output this time
kataLog.Logger.Out = buf
fn, ok := kataCheckCLICommand.Action.(func(context *cli.Context) error)
assert.True(ok)
err = fn(ctx)
assert.NoError(err)
output := buf.String()
for _, c := range cpuData {
assert.True(findAnchoredString(output, c.vendorID))
for _, flag := range strings.Fields(c.flags) {
assert.True(findAnchoredString(output, flag))
}
}
for _, m := range moduleData {
name := path.Base(m.path)
assert.True(findAnchoredString(output, name))
}
}
func TestCheckCheckKernelModulesNoNesting(t *testing.T) {
assert := assert.New(t)
dir, err := ioutil.TempDir("", "")
if err != nil {
t.Fatal(err)
}
defer os.RemoveAll(dir)
savedSysModuleDir := sysModuleDir
savedProcCPUInfo := procCPUInfo
cpuInfoFile := filepath.Join(dir, "cpuinfo")
// XXX: override
sysModuleDir = filepath.Join(dir, "sys/module")
procCPUInfo = cpuInfoFile
defer func() {
sysModuleDir = savedSysModuleDir
procCPUInfo = savedProcCPUInfo
}()
err = os.MkdirAll(sysModuleDir, testDirMode)
if err != nil {
t.Fatal(err)
}
requiredModules := map[string]kernelModule{
"kvm_intel": {
desc: "Intel KVM",
parameters: map[string]string{
"nested": "Y",
"unrestricted_guest": "Y",
},
},
}
actualModuleData := []testModuleData{
{filepath.Join(sysModuleDir, "kvm"), true, ""},
{filepath.Join(sysModuleDir, "kvm_intel"), true, ""},
{filepath.Join(sysModuleDir, "kvm_intel/parameters/unrestricted_guest"), false, "Y"},
// XXX: force a warning
{filepath.Join(sysModuleDir, "kvm_intel/parameters/nested"), false, "N"},
}
vendor := "GenuineIntel"
flags := "vmx lm sse4_1 hypervisor"
_, err = checkKernelModules(requiredModules, archKernelParamHandler)
// no cpuInfoFile yet
assert.Error(err)
createModules(assert, cpuInfoFile, actualModuleData)
err = makeCPUInfoFile(cpuInfoFile, vendor, flags)
assert.NoError(err)
count, err := checkKernelModules(requiredModules, archKernelParamHandler)
assert.NoError(err)
assert.Equal(count, uint32(0))
// create buffer to save logger output
buf := &bytes.Buffer{}
savedLogOutput := kataLog.Logger.Out
defer func() {
kataLog.Logger.Out = savedLogOutput
}()
kataLog.Logger.Out = buf
count, err = checkKernelModules(requiredModules, archKernelParamHandler)
assert.NoError(err)
assert.Equal(count, uint32(0))
re := regexp.MustCompile(`\bwarning\b.*\bnested\b`)
matches := re.FindAllStringSubmatch(buf.String(), -1)
assert.NotEmpty(matches)
}
func TestCheckCheckKernelModulesNoUnrestrictedGuest(t *testing.T) {
assert := assert.New(t)
dir, err := ioutil.TempDir("", "")
if err != nil {
t.Fatal(err)
}
defer os.RemoveAll(dir)
savedSysModuleDir := sysModuleDir
savedProcCPUInfo := procCPUInfo
cpuInfoFile := filepath.Join(dir, "cpuinfo")
// XXX: override
sysModuleDir = filepath.Join(dir, "sys/module")
procCPUInfo = cpuInfoFile
defer func() {
sysModuleDir = savedSysModuleDir
procCPUInfo = savedProcCPUInfo
}()
err = os.MkdirAll(sysModuleDir, testDirMode)
if err != nil {
t.Fatal(err)
}
requiredModules := map[string]kernelModule{
"kvm_intel": {
desc: "Intel KVM",
parameters: map[string]string{
"nested": "Y",
"unrestricted_guest": "Y",
},
},
}
actualModuleData := []testModuleData{
{filepath.Join(sysModuleDir, "kvm"), true, ""},
{filepath.Join(sysModuleDir, "kvm_intel"), true, ""},
{filepath.Join(sysModuleDir, "kvm_intel/parameters/nested"), false, "Y"},
// XXX: force a failure on non-VMM systems
{filepath.Join(sysModuleDir, "kvm_intel/parameters/unrestricted_guest"), false, "N"},
}
vendor := "GenuineIntel"
flags := "vmx lm sse4_1"
_, err = checkKernelModules(requiredModules, archKernelParamHandler)
// no cpuInfoFile yet
assert.Error(err)
err = makeCPUInfoFile(cpuInfoFile, vendor, flags)
assert.NoError(err)
createModules(assert, cpuInfoFile, actualModuleData)
count, err := checkKernelModules(requiredModules, archKernelParamHandler)
assert.NoError(err)
// fails due to unrestricted_guest not being available
assert.Equal(count, uint32(1))
// pretend test is running under a hypervisor
flags += " hypervisor"
// recreate
err = makeCPUInfoFile(cpuInfoFile, vendor, flags)
assert.NoError(err)
// create buffer to save logger output
buf := &bytes.Buffer{}
savedLogOutput := kataLog.Logger.Out
defer func() {
kataLog.Logger.Out = savedLogOutput
}()
kataLog.Logger.Out = buf
count, err = checkKernelModules(requiredModules, archKernelParamHandler)
// no error now because running under a hypervisor
assert.NoError(err)
assert.Equal(count, uint32(0))
re := regexp.MustCompile(`\bwarning\b.*\bunrestricted_guest\b`)
matches := re.FindAllStringSubmatch(buf.String(), -1)
assert.NotEmpty(matches)
}
func TestCheckHostIsVMContainerCapable(t *testing.T) {
assert := assert.New(t)
dir, err := ioutil.TempDir("", "")
if err != nil {
t.Fatal(err)
}
defer os.RemoveAll(dir)
savedSysModuleDir := sysModuleDir
savedProcCPUInfo := procCPUInfo
cpuInfoFile := filepath.Join(dir, "cpuinfo")
// XXX: override
sysModuleDir = filepath.Join(dir, "sys/module")
procCPUInfo = cpuInfoFile
defer func() {
sysModuleDir = savedSysModuleDir
procCPUInfo = savedProcCPUInfo
}()
err = os.MkdirAll(sysModuleDir, testDirMode)
if err != nil {
t.Fatal(err)
}
cpuData := []testCPUData{
{"", "", true},
{"Intel", "", true},
{"GenuineIntel", "", true},
{"GenuineIntel", "lm", true},
{"GenuineIntel", "lm vmx", true},
{"GenuineIntel", "lm vmx sse4_1", false},
}
moduleData := []testModuleData{
{filepath.Join(sysModuleDir, "kvm"), true, ""},
{filepath.Join(sysModuleDir, "kvm_intel"), true, ""},
{filepath.Join(sysModuleDir, "kvm_intel/parameters/nested"), false, "Y"},
{filepath.Join(sysModuleDir, "kvm_intel/parameters/unrestricted_guest"), false, "Y"},
}
setupCheckHostIsVMContainerCapable(assert, cpuInfoFile, cpuData, moduleData)
// remove the modules to force a failure
err = os.RemoveAll(sysModuleDir)
assert.NoError(err)
details := vmContainerCapableDetails{
cpuInfoFile: cpuInfoFile,
requiredCPUFlags: archRequiredCPUFlags,
requiredCPUAttribs: archRequiredCPUAttribs,
requiredKernelModules: archRequiredKernelModules,
}
err = hostIsVMContainerCapable(details)
assert.Error(err)
}
func TestArchKernelParamHandler(t *testing.T) {
assert := assert.New(t)
type testData struct {
onVMM bool
fields logrus.Fields
msg string
expectIgnore bool
}
data := []testData{
{true, logrus.Fields{}, "", false},
{false, logrus.Fields{}, "", false},
{
false,
logrus.Fields{
// wrong type
"parameter": 123,
},
"foo",
false,
},
{
false,
logrus.Fields{
"parameter": "unrestricted_guest",
},
"",
false,
},
{
true,
logrus.Fields{
"parameter": "unrestricted_guest",
},
"",
true,
},
{
false,
logrus.Fields{
"parameter": "nested",
},
"",
true,
},
}
for i, d := range data {
result := archKernelParamHandler(d.onVMM, d.fields, d.msg)
if d.expectIgnore {
assert.True(result, "test %d (%+v)", i, d)
} else {
assert.False(result, "test %d (%+v)", i, d)
}
}
}
func TestKvmIsUsable(t *testing.T) {
assert := assert.New(t)
dir, err := ioutil.TempDir("", "")
if err != nil {
t.Fatal(err)
}
defer os.RemoveAll(dir)
savedKvmDevice := kvmDevice
fakeKVMDevice := filepath.Join(dir, "kvm")
kvmDevice = fakeKVMDevice
defer func() {
kvmDevice = savedKvmDevice
}()
err = kvmIsUsable()
assert.Error(err)
err = createEmptyFile(fakeKVMDevice)
assert.NoError(err)
err = kvmIsUsable()
assert.Error(err)
}