mirror of
https://github.com/k3s-io/kubernetes.git
synced 2026-01-04 23:17:50 +00:00
Do not bind block PV/PVCs when block feature gate is off
This commit is contained in:
@@ -268,11 +268,7 @@ func checkVolumeSatisfyClaim(volume *v1.PersistentVolume, claim *v1.PersistentVo
|
||||
return fmt.Errorf("storageClassName does not match")
|
||||
}
|
||||
|
||||
isMismatch, err := pvutil.CheckVolumeModeMismatches(&claim.Spec, &volume.Spec)
|
||||
if err != nil {
|
||||
return fmt.Errorf("error checking volumeMode: %v", err)
|
||||
}
|
||||
if isMismatch {
|
||||
if pvutil.CheckVolumeModeMismatches(&claim.Spec, &volume.Spec) {
|
||||
return fmt.Errorf("incompatible volumeMode")
|
||||
}
|
||||
|
||||
@@ -589,7 +585,7 @@ func (ctrl *PersistentVolumeController) syncVolume(volume *v1.PersistentVolume)
|
||||
}
|
||||
return nil
|
||||
} else if claim.Spec.VolumeName == "" {
|
||||
if isMismatch, err := pvutil.CheckVolumeModeMismatches(&claim.Spec, &volume.Spec); err != nil || isMismatch {
|
||||
if pvutil.CheckVolumeModeMismatches(&claim.Spec, &volume.Spec) {
|
||||
// Binding for the volume won't be called in syncUnboundClaim,
|
||||
// because findBestMatchForClaim won't return the volume due to volumeMode mismatch.
|
||||
volumeMsg := fmt.Sprintf("Cannot bind PersistentVolume to requested PersistentVolumeClaim %q due to incompatible volumeMode.", claim.Name)
|
||||
|
||||
Reference in New Issue