Commit Graph

42 Commits

Author SHA1 Message Date
Kubernetes Prow Robot
8f7ccf8d4c Merge pull request #69036 from wackxu/snapshottest
add e2e test for snapshot
2019-02-08 13:14:04 -08:00
Kubernetes Prow Robot
eac19a3ab9 Merge pull request #73616 from dims/move-part-of-kubelet-apis-well-known-lables
move pkg/kubelet/apis/well_known_labels.go to staging/src/k8s.io/api/core/v1/
2019-02-07 19:44:34 -08:00
Yecheng Fu
aa87e4b57c Implement localDriver 2019-02-06 12:28:28 +08:00
Davanum Srinivas
b975573385 move pkg/kubelet/apis/well_known_labels.go to staging/src/k8s.io/api/core/v1/
Co-Authored-By: Weibin Lin <linweibin1@huawei.com>

Change-Id: I163b2f2833e6b8767f72e2c815dcacd0f4e504ea
2019-02-05 13:39:07 -05:00
xushiwei
7280fcef5c address reviewer comments 2019-02-01 16:34:16 +08:00
xushiwei
3410d435ed add snapshot e2e 2019-01-30 19:04:45 +08:00
Masaki Kimura
b152d435ae Update fsType parameter for csi v1.0 provisioner 2019-01-23 05:26:55 +00:00
Masaki Kimura
30ad1028eb Move xfs test skip logic from driver to testsuites 2019-01-23 05:17:06 +00:00
Masaki Kimura
398bf3929f Skip XFS test for csi gce-pd driver on COS 2019-01-23 05:15:24 +00:00
Masaki Kimura
b767dbdeb5 Fix volumes e2e test to check fsType 2019-01-23 05:12:37 +00:00
Cheng Xing
12ece9dacb CSI topology e2e tests 2019-01-11 18:36:06 -08:00
Kubernetes Prow Robot
5acac9b3e2 Merge pull request #70439 from jsafrane/worlload-test
CSI: Add test for passing Pod information in NodePublish call
2019-01-07 12:08:51 -08:00
Jan Safranek
e1556c1549 Fix hostpath driver name 2019-01-04 17:26:24 +01:00
Jan Safranek
d617dcb1e0 CSI: Add test for passing Pod information in NodePublish call 2019-01-02 16:11:41 +01:00
Patrick Ohly
98ba1d8519 e2e/storage: reset driver config in the test suite
PR #70862 made each driver responsible for resetting its config, but
as it turned out, one place was missed in that PR: the in-tree gcepd
sets a node selector. Not resetting that caused other tests to fail
randomly depending on test execution order.

Now the test suite resets the config by taking a copy after setting up
the driver and restoring that copy before each test.

Long term the intention is to separate the entire test config from the
static driver info (https://github.com/kubernetes/kubernetes/issues/72288),
but for now resetting the config is the fastest way to fix the test flake.

Fixes: #72378
2018-12-28 22:44:09 +01:00
Patrick Ohly
ac8ac8ee6c e2e: update bazel BUILD files
Generated via hack/update-bazel.sh.
2018-12-21 10:30:10 +01:00
Patrick Ohly
3253e9ab6b e2e/storage: refactor test config
Exposing framework.VolumeTestConfig as part of the testsuite package
API was confusing because it was unclear which of the values in it
really have an effect. How it was set also was a bit awkward: a test
driver had a copy that had to be overwritten at test runtime and then
might have been updated and/or overwritten again by the driver.

Now testsuites has its own test config structure. It contains the
values that might have to be set dynamically at runtime. Instead of
overwriting a copy of that struct inside the test driver, the test
driver takes some common defaults (specifically, the framework pointer
and the prefix) when it gets initialized and then manages its own
copy. For example, the hostpath driver has to lock the pods to a
single node.

framework.VolumeTestConfig is still used internally and test drivers
can decide to run tests with a fully populated instance if needed (for
example, after setting up an NFS server).
2018-12-21 10:30:06 +01:00
Patrick Ohly
dfcf2ca345 e2e/storage: separate generic testsuites from specific drivers
This makes it possible to use the testsuites package out-of-tree
without pulling in unnecessary dependencies and code (in
test/e2e/storage/vsphere) that defines tests that are not wanted in a
custom test suite.
2018-12-20 13:41:48 +01:00
Patrick Ohly
41ab9449ed e2e/storage: drivers determine the claim size
Different drivers support different volume sizes. Some have certain
minimum sizes, some maximum sizes. Instead of hard-coding some kind of
default into the testsuites, now each driver that supports dynamic
provisioning has to provide the size.
2018-12-20 13:41:48 +01:00
Patrick Ohly
5349ce75fa e2e/storage: remove code duplication
The setup of the V0 hostpath driver was done with copy-and-paste and
then changing just the driver name and the manifests. The same can be
achieved by making the base struct a bit more configurable, which
simplifies future changes (less code).

Renaming the provisioner container was unnecessary and was reverted to
make it possible to use the same patch configuration.

While at it, also fix the InitHostV0PathCSIDriver typo.
2018-12-20 13:41:48 +01:00
k8s-ci-robot
3156df3e80 Merge pull request #71537 from davidz627/fix/updateGCE
Create cloud-sa on GCE PD Driver creation
2018-11-30 08:20:29 -08:00
Michelle Au
03065a1bde Refactor driverinfo feature support into capabilities map 2018-11-29 11:10:06 -08:00
David Zhu
67a40cd3cc Do GCE Secret setup in driver creation instead of skip test 2018-11-29 10:51:01 -08:00
saad-ali
aa8244beb5 Modify CSI to handle both 0.3 and 1.0
Modify the CSI volume plugin to handle CSI version 0.x as well as 1.x
2018-11-21 18:37:31 -08:00
saad-ali
503f654d7a Update CSI tests to point to 1.0.0 external bits. 2018-11-15 20:01:50 -08:00
Michelle Au
63068be7ef Remove serial from gcepd-external tests 2018-11-13 16:42:57 -08:00
k8s-ci-robot
3c10143967 Merge pull request #60195 from humblec/glusterfs-pvspec-3
Refactor GlusterFS PV spec.
2018-11-08 00:24:39 -08:00
Masaki Kimura
d33211dc44 Fix test driver's unique name consistent
Fixes: #70760
2018-11-07 22:24:48 +00:00
Masaki Kimura
b89b367247 Make csi drivers and in-tree drivers share e2e tests 2018-11-07 15:42:58 +00:00
Humble Chirammal
bdb051c72d Refactor GlusterFS PV spec.
This patch introduces glusterfsPersistentVolumeSource addition
to glusterfsVolumeSource. All fields remains same as glusterfsVolumeSource
with an addition of a new field
called `EndpointsNamespace` to define namespace of endpoint in the
spec.

Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
2018-11-06 15:51:01 +05:30
Antonio Murdaca
fc80120a0f test/e2e/storage: use relatime for checking NFS options
Signed-off-by: Antonio Murdaca <runcom@redhat.com>
Signed-off-by: Antonio Murdaca <runcom@linux.com>
2018-10-25 20:44:33 +02:00
Masaki Kimura
4fcb36e205 Move minimum set of dynamic provisioning e2e test to testsuites 2018-10-22 16:04:43 +00:00
k8s-ci-robot
ae935d7293 Merge pull request #68569 from davidz627/fix/driverTestResources
Fix storage test framework leaking resources on cleanup
2018-09-12 21:44:42 -07:00
David Zhu
5155e1b5d9 Test Resource fix for all non-GCE In-tree drivers 2018-09-12 13:59:53 -07:00
David Zhu
725d5ebda4 Fix test framework to pass generic driver specific test specific resources. Fix GCE PD resource leak 2018-09-12 11:29:35 -07:00
David Zhu
24f67fd845 Ignore not found endpoint on deletion 2018-09-10 11:34:41 -07:00
David Zhu
face1ead9c Fixed error message reporting for Gluster driver tests 2018-09-06 17:27:28 -07:00
Matthew Wong
5d877436bf Update external provisioner test to use latest nfs-provisioner 2018-08-31 16:26:02 -04:00
Kubernetes Submit Queue
07f68ea842 Merge pull request #68099 from mkimuram/issue/68093
Automatic merge from submit-queue. If you want to cherry-pick this change to another branch, please follow the instructions here: https://github.com/kubernetes/community/blob/master/contributors/devel/cherry-picks.md.

Fix hostpath subpath reconstruction tests are failing

**What this PR does / why we need it**:
Fix hostpath subpath reconstruction tests are failing

**Which issue(s) this PR fixes** *(optional, in `fixes #<issue number>(, fixes #<issue_number>, ...)` format, will close the issue(s) when PR gets merged)*:
Fixes: #68093

**Special notes for your reviewer**:
/sig storage

**Release note**:
```release-note
NONE
```
2018-08-30 18:34:42 -07:00
Masaki Kimura
79230ee56e Fix hostpath subpath reconstruction tests are failing
Fixes: #68093
2018-08-30 22:53:59 +00:00
Michelle Au
233db366cc Fix multizone gce pd subpath test 2018-08-30 13:53:04 -07:00
Masaki Kimura
877ed5c22d Refactor volume test in a similar way to csi tests
Refactoring for non-csi e2e test similar to below commit in csi e2e test.
4d11dab272 (diff-0d9ecaa3e6a0297186ad33f57aad472e)

Scopes for this refactoring are below four files:
  - test/e2e/storage/volumes.go
  - test/e2e/storage/volume_io.go
  - test/e2e/storage/persistent_volumes-volumemode.go
  - test/e2e/storage/subpath.go

fixes: #66571
2018-08-29 14:39:01 +00:00