kubernetes/test/e2e/storage/vsphere/pvc_label_selector.go
Jan Safranek ba099644b2 Remove global framework variable
`f framework.Framework` does not need to be global, it's used only on a few
places.

This fixes vSphereDriver.PrepareTest() in in_tree.go that schedules
ginkgo.DeferCleanup() that uses the global `f` variable, but its value is not
valid at the time of ginkgo cleanup.
2023-02-20 11:00:12 +01:00

154 lines
6.0 KiB
Go

/*
Copyright 2017 The Kubernetes Authors.
Licensed under the Apache License, Version 2.0 (the "License");
you may not use this file except in compliance with the License.
You may obtain a copy of the License at
http://www.apache.org/licenses/LICENSE-2.0
Unless required by applicable law or agreed to in writing, software
distributed under the License is distributed on an "AS IS" BASIS,
WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
See the License for the specific language governing permissions and
limitations under the License.
*/
package vsphere
import (
"context"
"time"
"github.com/onsi/ginkgo/v2"
v1 "k8s.io/api/core/v1"
metav1 "k8s.io/apimachinery/pkg/apis/meta/v1"
clientset "k8s.io/client-go/kubernetes"
"k8s.io/kubernetes/test/e2e/framework"
e2enode "k8s.io/kubernetes/test/e2e/framework/node"
e2epv "k8s.io/kubernetes/test/e2e/framework/pv"
e2eskipper "k8s.io/kubernetes/test/e2e/framework/skipper"
"k8s.io/kubernetes/test/e2e/storage/utils"
admissionapi "k8s.io/pod-security-admission/api"
)
/*
This is a function test for Selector-Label Volume Binding Feature
Test verifies volume with the matching label is bounded with the PVC.
Test Steps
----------
1. Create VMDK.
2. Create pv with label volume-type:ssd, volume path set to vmdk created in previous step, and PersistentVolumeReclaimPolicy is set to Delete.
3. Create PVC (pvcVvol) with label selector to match with volume-type:vvol
4. Create PVC (pvcSsd) with label selector to match with volume-type:ssd
5. Wait and verify pvSsd is bound with PV.
6. Verify Status of pvcVvol is still pending.
7. Delete pvcSsd.
8. verify associated pv is also deleted.
9. delete pvcVvol
*/
var _ = utils.SIGDescribe("PersistentVolumes [Feature:vsphere][Feature:LabelSelector]", func() {
f := framework.NewDefaultFramework("pvclabelselector")
f.NamespacePodSecurityEnforceLevel = admissionapi.LevelPrivileged
var (
c clientset.Interface
ns string
pvSsd *v1.PersistentVolume
pvcSsd *v1.PersistentVolumeClaim
pvcVvol *v1.PersistentVolumeClaim
volumePath string
ssdlabels map[string]string
vvollabels map[string]string
err error
nodeInfo *NodeInfo
)
ginkgo.BeforeEach(func(ctx context.Context) {
e2eskipper.SkipUnlessProviderIs("vsphere")
c = f.ClientSet
ns = f.Namespace.Name
Bootstrap(f)
nodeInfo = GetReadySchedulableRandomNodeInfo(ctx, c)
framework.ExpectNoError(e2enode.WaitForAllNodesSchedulable(ctx, c, f.Timeouts.NodeSchedulable))
ssdlabels = make(map[string]string)
ssdlabels["volume-type"] = "ssd"
vvollabels = make(map[string]string)
vvollabels["volume-type"] = "vvol"
})
ginkgo.Describe("Selector-Label Volume Binding:vsphere [Feature:vsphere]", func() {
ginkgo.AfterEach(func(ctx context.Context) {
ginkgo.By("Running clean up actions")
if framework.ProviderIs("vsphere") {
testCleanupVSpherePVClabelselector(ctx, c, ns, nodeInfo, volumePath, pvSsd, pvcSsd, pvcVvol)
}
})
ginkgo.It("should bind volume with claim for given label", func(ctx context.Context) {
volumePath, pvSsd, pvcSsd, pvcVvol, err = testSetupVSpherePVClabelselector(ctx, c, nodeInfo, ns, ssdlabels, vvollabels)
framework.ExpectNoError(err)
ginkgo.By("wait for the pvcSsd to bind with pvSsd")
framework.ExpectNoError(e2epv.WaitOnPVandPVC(ctx, c, f.Timeouts, ns, pvSsd, pvcSsd))
ginkgo.By("Verify status of pvcVvol is pending")
err = e2epv.WaitForPersistentVolumeClaimPhase(ctx, v1.ClaimPending, c, ns, pvcVvol.Name, 3*time.Second, 300*time.Second)
framework.ExpectNoError(err)
ginkgo.By("delete pvcSsd")
framework.ExpectNoError(e2epv.DeletePersistentVolumeClaim(ctx, c, pvcSsd.Name, ns), "Failed to delete PVC ", pvcSsd.Name)
ginkgo.By("verify pvSsd is deleted")
err = e2epv.WaitForPersistentVolumeDeleted(ctx, c, pvSsd.Name, 3*time.Second, 300*time.Second)
framework.ExpectNoError(err)
volumePath = ""
ginkgo.By("delete pvcVvol")
framework.ExpectNoError(e2epv.DeletePersistentVolumeClaim(ctx, c, pvcVvol.Name, ns), "Failed to delete PVC ", pvcVvol.Name)
})
})
})
func testSetupVSpherePVClabelselector(ctx context.Context, c clientset.Interface, nodeInfo *NodeInfo, ns string, ssdlabels map[string]string, vvollabels map[string]string) (volumePath string, pvSsd *v1.PersistentVolume, pvcSsd *v1.PersistentVolumeClaim, pvcVvol *v1.PersistentVolumeClaim, err error) {
ginkgo.By("creating vmdk")
volumePath, err = nodeInfo.VSphere.CreateVolume(&VolumeOptions{}, nodeInfo.DataCenterRef)
if err != nil {
return
}
ginkgo.By("creating the pv with label volume-type:ssd")
pvSsd = getVSpherePersistentVolumeSpec(volumePath, v1.PersistentVolumeReclaimDelete, ssdlabels)
pvSsd, err = c.CoreV1().PersistentVolumes().Create(ctx, pvSsd, metav1.CreateOptions{})
if err != nil {
return
}
ginkgo.By("creating pvc with label selector to match with volume-type:vvol")
pvcVvol = getVSpherePersistentVolumeClaimSpec(ns, vvollabels)
pvcVvol, err = c.CoreV1().PersistentVolumeClaims(ns).Create(ctx, pvcVvol, metav1.CreateOptions{})
if err != nil {
return
}
ginkgo.By("creating pvc with label selector to match with volume-type:ssd")
pvcSsd = getVSpherePersistentVolumeClaimSpec(ns, ssdlabels)
pvcSsd, err = c.CoreV1().PersistentVolumeClaims(ns).Create(ctx, pvcSsd, metav1.CreateOptions{})
return
}
func testCleanupVSpherePVClabelselector(ctx context.Context, c clientset.Interface, ns string, nodeInfo *NodeInfo, volumePath string, pvSsd *v1.PersistentVolume, pvcSsd *v1.PersistentVolumeClaim, pvcVvol *v1.PersistentVolumeClaim) {
ginkgo.By("running testCleanupVSpherePVClabelselector")
if len(volumePath) > 0 {
nodeInfo.VSphere.DeleteVolume(volumePath, nodeInfo.DataCenterRef)
}
if pvcSsd != nil {
framework.ExpectNoError(e2epv.DeletePersistentVolumeClaim(ctx, c, pvcSsd.Name, ns), "Failed to delete PVC ", pvcSsd.Name)
}
if pvcVvol != nil {
framework.ExpectNoError(e2epv.DeletePersistentVolumeClaim(ctx, c, pvcVvol.Name, ns), "Failed to delete PVC ", pvcVvol.Name)
}
if pvSsd != nil {
framework.ExpectNoError(e2epv.DeletePersistentVolume(ctx, c, pvSsd.Name), "Failed to delete PV ", pvSsd.Name)
}
}