Because it is not configurable, config tool might not need to
define DM_OWNED_GUEST_FLAG_MASK. So we remove it in tool.
Tracked-On: #6366
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
GUEST_FLAG_SECURITY_VM only for pre-launch vm, should not be
programmed by device model, so we remove it in DM_OWNED_GUEST_FLAG_MASK.
Tracked-On: #6366
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
Get the integrated GPU bdf by looking for device from board.xml and extract the
BDF from device address.
Tracked-On: #6855
Signed-off-by: Yang,Yu-chu <yu-chu.yang@intel.com>
remove CONFIG_MAX_IR_ENTRIES the related python code, schema and
all existing scenario XML files since PR #6809 have changed it.
Tracked-On: #6745
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
remove LOW_RAM_SIZE in the related python code, schema and
all existing scenario XMLs because PR #6791 have removed it.
Tracked-On: #6805
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
Add a configuration to support companion VM.
Tracked-On: #6571
Signed-off-by: Jie Deng <jie.deng@intel.com>
Reviewed-by: Wang, Yu1 <yu1.wang@intel.com>
Add two VM flags for x86_tee. GUEST_FLAG_TEE for TEE VM,
GUEST_FLAG_REE for normal rich VM.
Tracked-On: #6571
Signed-off-by: Jie Deng <jie.deng@intel.com>
Reviewed-by: Wang, Yu1 <yu1.wang@intel.com>
Add assert for below invalid scenario:
1. Two or more pre-launched RTVM
2. One pre-launched RTVM and one or more post-launched RTVM
Tracked-On: #6685
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
1. remove CONFIG_KATA_VM, CONFIG_MAX_KATA_VM_NUM and KATA_VM
related code.
2. remove KATA_VM in scenario xml files.
3. remove KATA vm type in UI.
4. remove UUID DB.
5. remove uuid in the launch script generation logic.
6. use vmname to identify a vm. (eg: <name>ACRN_SOS_VM</name>)
add the check logic to ensure vm name is a must-set item, not duplicated,
and the string length is [1-15] and the whitespace is not allowed.
7. enlarge the max VM num to 32.
Tracked-On: #6685
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
Rename function name to get-common-clos-count and refine the
calculation. Some platforms have odd clos counts. Using "floor" to get
integer numbers for macros.
Tracked-On: #6755
Signed-off-by: Yang,Yu-chu <yu-chu.yang@intel.com>
1. ensure cpu affinity in launch xml is subset of its scenario settings.
2. cpu_affinity is a must have parameter for acrn_dm, if the user did not provide cpu affinity in launch xml, load it from scenario settings.
Tracked-On: #6724
Signed-off-by: Weiyi Feng <weiyix.feng@intel.com>
when we add two or more virtio block devices and rename them for a VM
in launch xml files, then generate launch scripts through the UI.
After ensuring the devices names are different, we repeat these operations
continuously. Finally we will get the duplicate PT_SLOT value for
different virtio block devices in a launch script. This is wrong.
After user click the "Generate Launch Script" button to generate the
launch scripts every time, we will reset PT_SLOT variate to fix the issue.
Tracked-On: #6767
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
Set hv features L1D_VMENTRY_ENABLED, MCE_ON_PSC_DISABLED and PTM
default value to 'y' in schema.
Tracked-On: #6793
Signed-off-by: Yang,Yu-chu <yu-chu.yang@intel.com>
Generate serial configuration file for service VM according
to scenario file and vUART ports base address allocated by
config tool.
Currently, some non-standard serial ports are emulated in
hypervisor and will be used to do communication between service
VM and user VM, so need to generate serial configuration file
to configure these serial ports for service VM.
v1-->v2:
Fix some type issues
Refine script code format
Tracked-On: #6652
Signed-off-by: Xiangyang Wu <xiangyang.wu@intel.com>
The pre-rtvm uses the RTCT tab to determine it's SSRAM address.
It was origionally duplicated from the host, and keeped its address
and layout.
To move the SSRAM area in ve820, we have to modify the guest's RTCT
tab first.
This patch uses the board_inspector's RTCT module to parse the host's
RTCT tab, and calculate the offset, then modifies the SSRAM/bin enties,
and saves it to the new RTCT bin file.
Tracked-On: #6674
Signed-off-by: Zhou, Wu <wu.zhou@intel.com>
Reviewed-by: Junjie Mao <junjie.mao@intel.com>
The config of MAX_EFI_MMAP_ENTRIES has been removed in hypervisor, so remove
this config in config_tools;
Tracked-On: #6442
Signed-off-by: Victor Sun <victor.sun@intel.com>
when we click the "Import XML" button to import the scenario xml file, then
click the "Export XML" to export the xml files, we will find some errors because
UI don't show the default value set in schema.
As a workaround, we call default_populator.py in UI to expand the default value
in the scenario XML file to fix the issue.
Tracked-On: #6292
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
This reverts commit 9e2edd5192.
Because config UI don't support multi legacy vuart in current logic,
we need to revert the commit to unblock UI.
Tracked-On: #6652
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
since PRs #6760 and #6765 have landed,
we also need to rename "UOS" to "user vm" in UI.
Tracked-On: #6744
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
when we add two or more virtio block devices and rename them for a VM
in launch xml files, then generate launch scripts through the UI.
After ensuring the devices names are different, we repeat these operations
continuously. Finally we will get the duplicate PT_SLOT value 30 for
different virtio block devices in a launch script. This is wrong.
As a workaround, we reassign PT_SLOT variate to reset it after the launch
script is generated every time.
Tracked-On: #6767
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
since PRs #6760 and #6747 have renamed uos to user_vm,
we also need to rename it in config UI.
Tracked-On: #6744
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
1. remove hvlog parameter in bootargs for all platforms.
2. update HV_RAM_START default address from 2MB to 4MB.
3. add the check that the HV_RAM_START value should be larger
than or equal to 2MB and 2MB aligned.
Tracked-On: #6663
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
In this patch, add vuart configuration in scenario XML of
each board to support communication between service VM and
user VM since system shutdown feature need to send commands
through this vuart communication channel.
The follow changes are made in this patch:
- Add multi legacy vuart for service VM for communication
- Add one legacy vuart for user VM for communication
- Add 8250.nr_uarts parameter in command line of service OS
Tracked-On: #6652
Signed-off-by: Xiangyang Wu <xiangyang.wu@intel.com>
1. "make clean && make BOARD=nuc11tnbi5 SCENARIO=shared" will generate the acrn debian package.
2. "make clean && make board_inspector" will generate the acrn board_inspector debian package
Tracked-On: #6688
Signed-off-by: Hu Fenglin <fenglin.hu@intel.com>
Rename SOS_VM type to SERVICE_VM
rename UOS to User VM in XML description
rename uos_thread_pid to user_vm_thread_pid
rename devname_uos to devname_user_vm
rename uosid to user_vmid
rename UOS_ACK to USER_VM_ACK
rename SOS_VM_CONFIG_CPU_AFFINITY to SERVICE_VM_CONFIG_CPU_AFFINITY
rename SOS_COM to SERVICE_VM_COM
rename SOS_UART1_VALID_NUM" to SERVICE_VM_UART1_VALID_NUM
rename SOS_BOOTARGS_DIFF to SERVICE_VM_BOOTARGS_DIFF
rename uos to user_vm in launch script and xml
Tracked-On: #6744
Signed-off-by: Liu Long <long.liu@linux.intel.com>
Reviewed-by: Geoffroy Van Cutsem <geoffroy.vancutsem@intel.com>
Rename SOS_VM_NUM to SERVICE_VM_NUM.
rename SOS_SOCKET_PORT to SERVICE_VM_SOCKET_PORT.
rename PROCESS_RUN_IN_SOS to PROCESS_RUN_IN_SERVICE_VM.
rename PCI_DEV_TYPE_SOSEMUL to PCI_DEV_TYPE_SERVICE_VM_EMUL.
rename SHUTDOWN_REQ_FROM_SOS to SHUTDOWN_REQ_FROM_SERVICE_VM.
rename PROCESS_RUN_IN_SOS to PROCESS_RUN_IN_SERVICE_VM.
rename SHUTDOWN_REQ_FROM_UOS to SHUTDOWN_REQ_FROM_USER_VM.
rename UOS_SOCKET_PORT to USER_VM_SOCKET_PORT.
rename SOS_CONSOLE to SERVICE_VM_OS_CONSOLE.
rename SOS_LCS_SOCK to SERVICE_VM_LCS_SOCK.
rename SOS_VM_BOOTARGS to SERVICE_VM_OS_BOOTARGS.
rename SOS_ROOTFS to SERVICE_VM_ROOTFS.
rename SOS_IDLE to SERVICE_VM_IDLE.
rename SEVERITY_SOS to SEVERITY_SERVICE_VM.
rename SOS_VM_UUID to SERVICE_VM_UUID.
rename SOS_REQ to SERVICE_VM_REQ.
rename RTCT_NATIVE_FILE_PATH_IN_SOS to RTCT_NATIVE_FILE_PATH_IN_SERVICE_VM.
rename CBC_REQ_T_UOS_ACTIVE to CBC_REQ_T_USER_VM_ACTIVE.
rename CBC_REQ_T_UOS_INACTIVE to CBC_REQ_T_USER_VM_INACTIV.
rename uos_active to user_vm_active.
Tracked-On: #6744
Signed-off-by: Liu Long <long.liu@linux.intel.com>
Reviewed-by: Geoffroy Van Cutsem <geoffroy.vancutsem@intel.com>
Improve the logging readibility for the Board Inspector tool by adding
a space after "Error:" and "Warning:" instead of have the text directly
attached to it.
Tracked-On: #6736
Signed-off-by: Geoffroy Van Cutsem <geoffroy.vancutsem@intel.com>
Commit 4a04fcc ("config_tools: skip remapping HW units with no devices under
scope") skips hardware remapping units without any device under its scope in the
config tools, which turns out to only work if the HV is not parsing the DMAR at
runtime.
This patch reverts the previous workaround and fixes the previous issue by
always initializing `dmar_hw_list.hw_ignore` when parsing DMAR. This ensures
that the DRHDx_IGNORE macro will always be emitted while DRHD_COUNT is not
impacted.
Fixes: 4a04fcc ("config_tools: skip remapping HW units with no devices under scope")
Tracked-On: #6709
Signed-off-by: Junjie Mao <junjie.mao@intel.com>
Fix a crash in the 'board_inspector.py' tool in case 'cpuid' is not
installed on the system.
The tools crashes because 'cpuid' is used before the check for
dependencies is done in the code. That check for dependencies is
done in the 'legacy/board_parser.py' file. But the native_check()
function that is called before it also expects the cpuid tool to
be installed.
The fix is to move the check for dependencies in the main
'board_inspector.py' file, before any other operation is done.
Tracked-On: #6719
Signed-off-by: Geoffroy Van Cutsem <geoffroy.vancutsem@intel.com>
We should generate new board xmls for cfl,whl and nuc11 because of the
board inspector changes. For the details refer to these RPs:#6699 #6710
Tracked-On:#6709
Signed-off-by: zhongzhenx.liu <zhongzhenx.liu@intel.com>
For vCAT, it may need to store more than MAX_VCPUS_PER_VM of closids,
change clos in vm_config.h to a pointer to accommodate this situation
Rename clos to pclosids
pclosids now is a pointer to an array of physical CLOSIDs that is defined
in vm_configurations.c by vmconfig. The number of elements in the array
must be equal to the value given by num_pclosids
Add max_type_pcbm (type: l2 or l3) to struct acrn_vm_config, which stores a bitmask
that selects/covers all the physical cache ways assigned to the VM
Change vmsr.c to accommodate this amended data structure
Change the config-tools to generate vm_configurations.c, and fill in the num_closids
and clos pointers based on the information from the scenario file.
Now vm_configurations.c.xsl generates all the clos related code so remove the same
code from misc_cfg.h.xsl.
Examples:
Scenario file:
<RDT>
<RDT_ENABLED>y</RDT_ENABLED>
<CDP_ENABLED>n</CDP_ENABLED>
<VCAT_ENABLED>y</VCAT_ENABLED>
<CLOS_MASK>0x7ff</CLOS_MASK>
<CLOS_MASK>0x7ff</CLOS_MASK>
<CLOS_MASK>0x7ff</CLOS_MASK>
<CLOS_MASK>0xff800</CLOS_MASK>
<CLOS_MASK>0xff800</CLOS_MASK>
<CLOS_MASK>0xff800</CLOS_MASK>
<CLOS_MASK>0xff800</CLOS_MASK>
<CLOS_MASK>0xff800</CLOS_MASK>
/RDT>
<vm id="0">
<guest_flags>
<guest_flag>GUEST_FLAG_VCAT_ENABLED</guest_flag>
</guest_flags>
<clos>
<vcpu_clos>3</vcpu_clos>
<vcpu_clos>4</vcpu_clos>
<vcpu_clos>5</vcpu_clos>
<vcpu_clos>6</vcpu_clos>
<vcpu_clos>7</vcpu_clos>
</clos>
</vm>
<vm id="1">
<clos>
<vcpu_clos>1</vcpu_clos>
<vcpu_clos>2</vcpu_clos>
</clos>
</vm>
vm_configurations.c (generated by config-tools) with the above vCAT config:
static uint16_t vm0_vcpu_clos[5U] = {3U, 4U, 5U, 6U, 7U};
static uint16_t vm1_vcpu_clos[2U] = {1U, 2U};
struct acrn_vm_config vm_configs[CONFIG_MAX_VM_NUM] = {
{
.guest_flags = (GUEST_FLAG_VCAT_ENABLED),
.pclosids = vm0_vcpu_clos,
.num_pclosids = 5U,
.max_l3_pcbm = 0xff800U,
},
{
.pclosids = vm1_vcpu_clos,
.num_pclosids = 2U,
},
};
Tracked-On: #5917
Signed-off-by: dongshen <dongsheng.x.zhang@intel.com>
Acked-by: Eddie Dong <eddie.dong@intel.com>
Add the VCAT_ENABLED element to RDTType so that user can enable/disable vCAT globally
Add the GUEST_FLAG_VCAT_ENABLED guest flag to enable/disable vCAT per-VM.
Currently we have the following per-VM clos element in scenario file for RDT use:
<clos>
<vcpu_clos>0</vcpu_clos>
<vcpu_clos>0</vcpu_clos>
</clos>
When the GUEST_FLAG_VCAT_ENABLED guest flag is not specified, clos is for RDT use,
vcpu_clos is per-CPU and it configures each CPU in VMs to a desired CLOS ID.
When the GUEST_FLAG_VCAT_ENABLED guest flag is specified, vCAT is enabled for this VM,
clos is for vCAT use, vcpu_clos is not per-CPU anymore in this case, just a list of
physical CLOSIDs (minimum 2) that are assigned to VMs for vCAT use. Each vcpu_clos
will be mapped to a virtual CLOSID, the first vcpu_clos is mapped to virtual CLOSID
0 and the second is mapped to virtual CLOSID 1, etc
Add xs:assert to prevent any problems with invalid configuration data for vCAT:
If any GUEST_FLAG_VCAT_ENABLED guest flag is specified, both RDT_ENABLED and VCAT_ENABLED
must be 'y'
If VCAT_ENABLED is 'y', RDT_ENABLED must be 'y' and CDP_ENABLED must be 'n'
For a vCAT VM, vcpu_clos cannot be set to CLOSID 0, CLOSID 0 is reserved to be used by hypervisor
For a vCAT VM, number of clos/vcpu_clos elements must be greater than 1
For a vCAT VM, each clos/vcpu_clos must be less than L2/L3 COS_MAX
For a vCAT VM, its clos/vcpu_clos elements cannot contain duplicate values
There should not be any CLOS IDs overlap between a vCAT VM and any other VMs
Tracked-On: #5917
Signed-off-by: dongshen <dongsheng.x.zhang@intel.com>
Acked-by: Eddie Dong <eddie.dong@intel.com>
1. remove HV_RAM_SIZE and CONFIG_HV_RAM_SIZE in the related python
code, schema and all existing scenario XMLs because PR 6664 has
changed it in HV side.
2. set HV_RAM_START default value to 2M.
Tracked-On: #6663
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
It is seen on some platforms that the ACPI DMAR tables will report
remapping hardware units that does not have any device under its scope,
which is not expected by the board inspector previously and thus causes the
tool to generate inconsistent configuration data.
This patch makes the board inspector skip such remapping hardware units. It
does not impact the functionality of the hypervisor as no device is managed
by those skipped remapping units.
Tracked-On: #6709
Signed-off-by: Junjie Mao <junjie.mao@intel.com>
In commit of 7cc9c8fe06
the pre-launched VM was set to ACPI HW Reduced platform, then the IRQ
would be allocated from 0 for PCI MSI devices. The Intel igb/igc driver
might get IRQ 8 when do request irq which would conflict with the irq
of RTC device:
[ 14.264954] genirq: Flags mismatch irq 8. 00000000 (enp0s8-TxRx-3) vs.
00000000 (rtc0)
[ 14.265411] ------------[ cut here ]------------
[ 14.265508] kernel BUG at drivers/pci/msi.c:376!
[ 14.265610] invalid opcode: 0000 [#1] PREEMPT SMP
[ 14.265710] CPU: 0 PID: 296 Comm: connmand Not tainted 5.10.52-acrn-sos
-dirty #72
[ 14.265863] RIP: 0010:free_msi_irqs+0x182/0x1b0
This patch will specify some legacy PnP device like UART and RTC in ACPI
DSDT table of pre-launched VM, so that IRQs from IOAPIC pin 4/3/8 could be
preserved before MSI device requesting IRQs.
Tracked-On: #6704
Signed-off-by: Victor Sun <victor.sun@intel.com>
Remove the restriction that SERIAL_CONSOLE needs to be ttys0, ttys1,
ttys2 or ttys3.
1. Lossen the restriction in xsd.
2. Rewrite the document.
3. Refine the intx.py. Refine the logic which take effect if the <irq>
is specified in "SOS_COM#_IRQ" for SOS VM's legacy vuart 0.
Tracked-On: #6610
Signed-off-by: Yang,Yu-chu <yu-chu.yang@intel.com>
add hybrid_rt.xml file under the generic_board folder so that
UI can call pre_rt_vm type when the user clicks 'Add a VM below'
button to add a new pre_rt_vm.
Tracked-On: #6292
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
call default_populator.py to expand the default value in the
scenario XML file to fix the issue that don't export xml successfully
in UI when user to click the 'Export XML' button to export scenario xml
file because that the unexpanded xml does not conform to schema check.
Tracked-On: #6292
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
According to TCG ACPI specification (version 1.2), the current revision of
TPM2 table, which has the optional log area fields, is 4. This patch
updates the revision of vTPM2 accordingly.
Tracked-On: #6288
Signed-off-by: Junjie Mao <junjie.mao@intel.com>
ACPI device drivers use both _HID and _CID to identify devices they
match. This patch copies _CID objects to vACPI devices so that guest
drivers can recognize the passthrough devices properly.
Tracked-On: #6288
Signed-off-by: Junjie Mao <junjie.mao@intel.com>
If a legacy vuart base is configured as "CONFIG_COM_BASE", allocate a
base with unused io-port address with length 0x10.
The post-launched VM's unused io-port address range is [0xD00, 0xFFFF].
The pre-launched VM's unused io-port address range is [0xD00, 0xFFFF]
but the passthrough devices' io-port address are reserved.
The SOS VM's unused io-port address range is [0xD00, 0xFFFF] but any
native devices' io-port address are reserved. However, the io-port
address which is passed through to any pre-launched is reusable.
Tracked-On: #6652
Signed-off-by: Yang,Yu-chu <yu-chu.yang@intel.com>
Expand the capacity of legacy vuarts per VM. This change is applied to
manual scenario xml editing only.
A SOS VM can choose io port 0x3F8, 0x2F8, 0x3E8, 0x2E8 by selecting
SOS_COM1_BASE, SOS_COM2_BASE, SOS_COM3_BASE, SOS_COM4_BASE respectively.
Non SOS VM can choose io port 0x3F8, 0x2F8, 0x3E8, 0x2E8 by selecting
COM1_BASE, COM2_BASE, COM3_BASE, COM4_BASE respectively.
For any type of VM, selecting "CONFIG_COM_BASE" allows configuration tool
to pick an available io port from hardcoded list:
['0xA000', '0xA010', '0xA020', '0xA030', '0xA040', '0xA050', '0xA060', '0xA070']
A SOS VM can choose irq 4 by selecting SOS_COM1_IRQ and SOS_COM3_IRQ, and choose irq 3 by selecting SOS_COM2_IRQ and SOS_COM4_IRQ.
Non SOS VM can choose irq 4 by selecting COM1_IRQ and COM3_IRQ, and choose irq 3 by selecting COM2_IRQ and COM4_IRQ.
For SOS VM, selecting "CONFIG_COM_IRQ" allows configuration tool
to pick an available irq based on AVAILABLE_IRQ_INFO. For non SOS VM, it
will allocate an available irq from [1, 15].
Tracked-On: #6652
Signed-off-by: Yang,Yu-chu <yu-chu.yang@intel.com>
1. move tgl-rvp and ehl-crb-b folders under data directory to 1source.
2. delete nuc7i7dnb and whl-ipc-i7 folders under data directory.
Tracked-On: #6315
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
Pass through the io-ports for the passthrough pci devices of
pre-launched VM.
Three parts to support this feature:
1. Identical map the pci devices io-port address for pre-launched VM
2. Set the io-ports address range to DSDT
3. Avoid to allocate the bar index for VMSIX
Tracked-On: #6620
Signed-off-by: Yang,Yu-chu <yu-chu.yang@intel.com>
Without this ``iomem=relaxed`` kernel parameter, the generated board XML
is essentially the same as having ``--basic`` when executing the board
inspector, i.e. the ACPI namespace will not be parsed. The generated
board XML may still work, but some functionality (e.g. passthru of TPM
and other PCI devices that need INTx) will no longer work due to lack of
hardware information.
Replacing PR #6618
Tracked-On: #5692
Signed-off-by: zhongzhenx.liu <zhongzhenx.liu@intel.com>
Signed-off-by: David B. Kinder <david.b.kinder@intel.com>
This patch adds a new priority based scheduler to support
vCPU scheduling based on their pre-configured priorities.
A vCPU can be running only if there is no higher priority
vCPU running on the same pCPU.
Tracked-On: #6571
Signed-off-by: Jie Deng <jie.deng@intel.com>
Simplify the statement by TPM2 enablement detection and present TPM2 device.
Remove the function and move the statement to misc_cfg.h.xsl
Tracked-On: #6562
Signed-off-by: Yang,Yu-chu <yu-chu.yang@intel.com>
The default value population algorithm introduced by commit
2bfaa34 ("config_tools: populate default values in scenario XML") only
populates default values to the first occurrence of a tag when the tag is
specified to allow multiple occurrences under an xs:all node. This may lead
to incomplete scenario XML as some of the default values are missed.
This patch fixes this issue by checking **all** nodes having the same tag
under a node specified by an xs:all schema.
Fixes: 2bfaa34 ("config_tools: populate default values in scenario XML")
Tracked-On: #6292
Signed-off-by: Junjie Mao <junjie.mao@intel.com>
The execution order of the "modprobe pci_stub" command is erroneous
in the launch script generation logic. The "modprobe pci_stub" command
should be executed before unbinding passthru devices, so we adjust the
command excution order.
Tracked-On: #6565
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
While we have default values of configuration entries stated in the schema
of scenario XMLs, today we still require user-given scenario XMLs to
contain literally ALL XML nodes. Missing of a single node will cause schema
validation errors even though we can use its default value defined in the
schema.
This patch allows user-given scenario XMLs to ignore nodes with default
values. It is done by adding the missing nodes, all containing the defined
default values, to the input scenario XML when copying it to the build
directory. This approach imposes no changes to either the schema or
subsequent scripts in the build system.
Tracked-On: #6292
Signed-off-by: Junjie Mao <junjie.mao@intel.com>
1. For initial UI, rename "ACRN Config" to "ACRN Configurator",
rename "Scenario Setting" to "Scenario Settings", rename "Launch Setting"
to "Launch Settings", and rename "Import Board info" to "Import Board XML";
2. For UI scenario selection, change title "Load Scenario Setting" to
"Load Default Scenario Settings", Change title "Save as" to "Save Scenario XML",
and rename "XML Name" to "Scenario XML Name";
7. For UI launch selection, rename "Load Launch setting" to
"Load Default Launch Settings", change title "Save as" to "Save Launch XML",
change "XML Name" to "Launch XML Name" and Change "Source Path" to "Launch XML Path".
Tracked-On: #6417
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
The pattern matching logic (used by 'tr') is erroneous in the launch
script generation logic. While its purpose is to return the CPU number
from the 'cpuX' string (where 'X' is the CPU number),
it does it incorrectly for any multiple of 10. Examples:
- Processing 'cpu10' returns 1 (instead of 10)
- Processing 'cpu20' returns 2 (instead of 20)
This patch changes the [1-99] pattern matching to [0-9] which fixes it.
This error led to the incorrect CPU cores being used (and offlined)
for some VMs which could lead to confusing problems especially when
an exclusive use of that CPU core was assumed and expected (e.g. RTVM).
when CONFIG_BOOTPARAM_HOTPLUG_CPU0 is turned on in the kernel,
there is a risk that we try to offline cpu0. So we also add extra check
for cpu0 to aviod the risk.
Tracked-On: #6482
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
The whitespaces between delimiter saperated elemnts of a list causes
acrn:get-common-clos-max and acrn:find-list-min returns unexpected
numbers.
Translate the whitespaces to nothing and rewrite acrn:find-list-min and
acrn:get-common-clos-max.
Tracked-On: #6515
Signed-off-by: Yang,Yu-chu <yu-chu.yang@intel.com>
rename the industry folder to shared folder ,and also rename the
logical_partition folder to partitioned under the generic_code directory.
Tracked-On: #6315
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
1. Rename industry.xml to shared.xml
2. Rename logical_partition.xml to partitioned.xml.
3. Update the name in view.py correspondingly.
Tracked-On: #6315
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
for ehl-crb-b platform, update sos rootfs from "dev/sda3"
to "/dev/nvme0n1p3" in hybrid.xml file.
Tracked-On: #6530
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
For SMBIOS and TPM, enable SECURITY_VM_FIXUP and add GUEST_FLAG_SECURITY_VM
flag in TGL hybrid_rt.xml. Then disable SECURITY_VM_FIXUP in TGL hybrid.xml
because it’s previously enabled in hybrid.xml instead of hybrid_rt.xml by
mistake.
Tracked-On: #6320
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
The bdf of gpu is not 00:02.0 for the new platform icx-rvp,
it is 05:00.0 now, so we remove the hardcode 00:02.0;
And change to get the gpu bdf from board.xml.
Tracked-On: #6357
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
This patch renames the GUEST_FLAG_TPM2_FIXUP to
GUEST_FLAG_SECURITY_VM.
v2 -> v3:
The "FIXUP" suffix is removed.
Tracked-On: #6320
Signed-off-by: Yifan Liu <yifan1.liu@intel.com>
1. set the content of the bootargs tag to empty for KERNEL_ELF type
in hybrid xml files.
2. update generic_board.xml with the latest nuc11tnbi5.xml to fix
compile fail issue.
Tracked-On: #6461
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
remove the log "<board>.xml has been generated successfully!" in
board_parser.py, because it only mean that the board xml file have
been created sucessfully here, not the all data have been appended
successfully and pretty formatted.
Tracked-On: #6315
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
1. as a workaround, comment the code to check MBA_DELAY tag when
creating a new scenario xml setting because of this tag are retrived
from scenario xml files in generic_board folder where it is removed
now.
2. update the template launch xml file names according the recent
update for launch xml files in generic folder.
Tracked-On: #6315
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
MAXIMUM_PA_WIDTH will be calculated from board information.
Tracked-On: #6357
Signed-off-by: Liang Yi <yi.liang@intel.com>
Signed-off-by: Junjie Mao <junjie.mao@intel.com>
It is used to specify the maximum number of EFI memmap entries.
On some platforms, like Tiger Lake, the number of EFI memmap entries
becomes 268 when the BIOS settings are changed.
The current value of MAX_EFI_MMAP_ENTRIES (256) defined in hypervisor
is not big enough to cover such cases.
As the number of EFI memmap entries depends on the platforms and the
BIOS settings, this patch introduces a new entry MAX_EFI_MMAP_ENTRIES
in configurations so that it can be adjusted for different cases.
Tracked-On: #6442
Signed-off-by: Shiqing Gao <shiqing.gao@intel.com>
Update lpc slot to origin value 1 from 31 in the script too,
because GOP driver has assumption to config space layout of
the device on 00:1f.0.
Tracked-On: #6340
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>
1. rename “cli.py” to “board_inspector.py”,
and update the script name in README file.
2. rename “app.py” to “acrn_configurator.py”.
Tracked-On: #6417
Signed-off-by: Kunhui-Li <kunhuix.li@intel.com>