mirror of
https://github.com/kata-containers/kata-containers.git
synced 2026-07-25 14:18:54 +00:00
qemu/machine: ARCHITECTURE.md Phase 4+5 status + auto mode note
Mark Phase 4 and Phase 5 complete (✅). Enumerate what each phase delivered vs. the original plan: Phase 4: NIC groups, prealloc fix, fixture corrections, GB300 dry-run, all 12 tests passing without #[ignore]. Phase 5: prealloc=on for hugepages, vCMDQ/vEGM wired end-to-end. Add "auto" mode note under Phase 4: the kata config fields cold_plug_vfio and hot_plug_vfio currently require an explicit topology string. An "auto" value is the natural next step once PlatformProbe is implemented to scan /sys/bus/pci/devices/ and classify devices; apply_host_defaults already contains the logic to derive the right topology. Update Phase 6 checklist: add PlatformProbe/"auto" wiring and switch-port topology (NVSwitch/DAN fan-out) as explicit deliverables. Add nic_smmu_groups to the HostTopology struct block. Assisted-by: Claude Sonnet 4.6 <noreply@anthropic.com> Signed-off-by: Zvonko Kaiser <zkaiser@nvidia.com>
This commit is contained in:
@@ -340,7 +340,13 @@ See [Config 7](#config-7--vegm-2-gpus-per-socket-4-gpus-2-sockets).
|
||||
/// Read from host sysfs and IOMMU group layout before constructing Platform.
|
||||
pub struct HostTopology {
|
||||
pub sockets: Vec<SocketInfo>,
|
||||
/// GPU groups: each maps to one pxb+smmuv3; GPUs emit 8 acpi-generic-initiator nodes.
|
||||
pub gpu_smmu_groups: Vec<GpuSmmuGroup>,
|
||||
/// NIC groups: each gets its own pxb+smmuv3 complex allocated after all GPU
|
||||
/// complexes in bus_nr ordering. NICs emit no acpi-generic-initiator links
|
||||
/// and no NUMA initiator nodes. Reuses GpuSmmuGroup struct for the same
|
||||
/// socket-affinity semantics; differentiated by field name.
|
||||
pub nic_smmu_groups: Vec<GpuSmmuGroup>,
|
||||
pub egm_sockets: Vec<EgmSocketInfo>,
|
||||
pub numa_distances: Vec<(u32, u32, u32)>, // (src, dst, val)
|
||||
/// Minimum pre-provisioned empty root-port count on Q35 pcie.0.
|
||||
@@ -797,25 +803,53 @@ each supported machine type and that `HostTopology` round-trips through
|
||||
`q35_vanilla_kata_x86`, `q35_coco_snp_single_gpu`,
|
||||
`q35_coco_tdx_8gpu_4nvswitch`, `q35_vanilla_8gpu_4nvswitch`.
|
||||
|
||||
### Phase 4 — Multi-RC PCIe and NUMA layout
|
||||
### Phase 4 — Multi-RC PCIe and NUMA layout ✅
|
||||
|
||||
- Emit `pxb-pcie` (with `numa_node=`) + per-RC `arm-smmuv3` from `PciTopology`.
|
||||
- Support N root ports per `PciRootComplex` (Config 3 shape: 2 GPUs per `SMMU`).
|
||||
- Add `VfioPciNoHotplug` with typed `IommufdRef` and `VfioDeviceKind`.
|
||||
- `VfioDeviceKind` enum drives device-type-specific emission (`vfio-pci-nohotplug`
|
||||
for Grace GPUs, `vfio-pci` for NICs/NvSwitch/GpuPci).
|
||||
- Emit NUMA nodes in the correct order (CpuMem → GPU initiators → memory-only).
|
||||
- `apply_host_defaults` wired end-to-end: Configs 1–4 golden fixtures pass.
|
||||
- `HostTopology::nic_smmu_groups` added: NICs get their own pxb+`smmuv3` complex
|
||||
but emit no `acpi-generic-initiator` links and no NUMA initiator nodes.
|
||||
- `apply_host_defaults` wired end-to-end: all 7 Grace configs pass.
|
||||
- `MemoryBackend::File { prealloc }` fixed: `prealloc=on` now emitted for hugepages.
|
||||
- GB300 dry-run fixture: `gb300_nvl_2gpu.args` — Grace + 2 B200 GPUs,
|
||||
`highmem-mmio-size=8T` (B200 BARs exceed the 4T window).
|
||||
- All 12 fixture tests pass without `#[ignore]`:
|
||||
`grace_1` through `grace_7`, `gb300_nvl_2gpu`, and 4 Q35 tests.
|
||||
|
||||
### Phase 5 — `vCMDQ` and vEGM
|
||||
**`"auto"` mode (Phase 4+):** The kata config fields `cold_plug_vfio` and
|
||||
`hot_plug_vfio` currently require an explicit topology string (`"root-port"`,
|
||||
`"switch-port"`, etc.). An `"auto"` value is the natural next step: once
|
||||
`PlatformProbe` is implemented to scan `/sys/bus/pci/devices/` and classify
|
||||
devices, `apply_host_defaults` already contains all the logic to derive the
|
||||
right topology automatically. `"auto"` will call the prober and select:
|
||||
- `root-port` for GPU-only workloads
|
||||
- `root-port + NIC pxb` when NICs are in `nic_smmu_groups`
|
||||
- `switch-port` (Phase 6+) for NVSwitch/DAN fan-out
|
||||
The prober is not implemented yet; `"auto"` is reserved and will error until
|
||||
`PlatformProbe::probe()` lands.
|
||||
>>>>>>> 208b1c739 (qemu/machine: ARCHITECTURE.md Phase 4+5 status + auto mode note)
|
||||
|
||||
- `SmmuV3 { cmdqv: true }` + `MemoryBackend::File { path: "/dev/hugepages/", … }`.
|
||||
- `AcpiPciNodeLink::EgmMemory` + per-socket `MemoryBackend::File { path: "/dev/egmN", … }`.
|
||||
### Phase 5 — `vCMDQ` and vEGM ✅
|
||||
|
||||
- `SmmuV3 { cmdqv: true }` + `MemoryBackend::File { path: "/dev/hugepages/", prealloc: true }`.
|
||||
- `AcpiPciNodeLink::EgmMemory` + per-socket `MemoryBackend::File { path: "/dev/egmN", is_egm: true }`.
|
||||
- `EgmSocketInfo` probe wired into `apply_host_defaults`.
|
||||
- Configs 5–7 golden fixtures pass.
|
||||
- `with_hugepages()` correctly sets `prealloc=on` on the emitted backend line.
|
||||
|
||||
### Phase 6 — Cleanup
|
||||
|
||||
- Delete dead code from `cmdline_generator.rs`.
|
||||
- Delete dead code from `cmdline_generator.rs` (strangle pattern: new Platform
|
||||
takes over one device class at a time; old code deleted when test coverage
|
||||
confirms parity).
|
||||
- Remove feature flags / compat shims introduced during migration.
|
||||
- Implement `PlatformProbe::probe()` and wire `"auto"` in `cold_plug_vfio` /
|
||||
`hot_plug_vfio` to call `apply_host_defaults` without manual topology config.
|
||||
- Add `switch-port` topology for NVSwitch/DAN fan-out
|
||||
(`pcie-root-port → x3130-upstream → N xio3130-downstream`).
|
||||
- Final golden-test sweep across all 7 Grace configs plus existing machine types.
|
||||
- Remove all TODOs and decision stubs from this document.
|
||||
|
||||
|
||||