Merge pull request #129723 from carlory/NFSPersistentVolumes

remove unrunnable tests from NFSPersistentVolumes
This commit is contained in:
Kubernetes Prow Robot 2025-01-24 09:35:28 -08:00 committed by GitHub
commit c5c19a6487
No known key found for this signature in database
GPG Key ID: B5690EEEBB952194

View File

@ -19,7 +19,6 @@ package storage
import (
"context"
"fmt"
"net"
"time"
"github.com/onsi/ginkgo/v2"
@ -28,15 +27,12 @@ import (
v1 "k8s.io/api/core/v1"
metav1 "k8s.io/apimachinery/pkg/apis/meta/v1"
"k8s.io/apimachinery/pkg/labels"
utilerrors "k8s.io/apimachinery/pkg/util/errors"
clientset "k8s.io/client-go/kubernetes"
"k8s.io/kubernetes/test/e2e/framework"
e2ekubesystem "k8s.io/kubernetes/test/e2e/framework/kubesystem"
e2enode "k8s.io/kubernetes/test/e2e/framework/node"
e2epod "k8s.io/kubernetes/test/e2e/framework/pod"
e2epv "k8s.io/kubernetes/test/e2e/framework/pv"
e2eskipper "k8s.io/kubernetes/test/e2e/framework/skipper"
e2essh "k8s.io/kubernetes/test/e2e/framework/ssh"
e2evolume "k8s.io/kubernetes/test/e2e/framework/volume"
"k8s.io/kubernetes/test/e2e/storage/utils"
admissionapi "k8s.io/pod-security-admission/api"
@ -48,34 +44,7 @@ type disruptiveTest struct {
runTest testBody
}
// checkForControllerManagerHealthy checks that the controller manager does not crash within "duration"
func checkForControllerManagerHealthy(ctx context.Context, duration time.Duration) error {
var PID string
cmd := "pidof kube-controller-manager"
for start := time.Now(); time.Since(start) < duration && ctx.Err() == nil; time.Sleep(5 * time.Second) {
result, err := e2essh.SSH(ctx, cmd, net.JoinHostPort(framework.APIAddress(), e2essh.SSHPort), framework.TestContext.Provider)
if err != nil {
// We don't necessarily know that it crashed, pipe could just be broken
e2essh.LogResult(result)
return fmt.Errorf("master unreachable after %v", time.Since(start))
} else if result.Code != 0 {
e2essh.LogResult(result)
return fmt.Errorf("SSH result code not 0. actually: %v after %v", result.Code, time.Since(start))
} else if result.Stdout != PID {
if PID == "" {
PID = result.Stdout
} else {
//its dead
return fmt.Errorf("controller manager crashed, old PID: %s, new PID: %s", PID, result.Stdout)
}
} else {
framework.Logf("kube-controller-manager still healthy after %v", time.Since(start))
}
}
return nil
}
var _ = utils.SIGDescribe("NFSPersistentVolumes", framework.WithDisruptive(), framework.WithFlaky(), func() {
var _ = utils.SIGDescribe("NFSPersistentVolumes", framework.WithDisruptive(), func() {
f := framework.NewDefaultFramework("disruptive-pv")
f.NamespacePodSecurityLevel = admissionapi.LevelPrivileged
@ -136,98 +105,6 @@ var _ = utils.SIGDescribe("NFSPersistentVolumes", framework.WithDisruptive(), fr
}
})
ginkgo.Context("when kube-controller-manager restarts", func() {
var (
diskName1, diskName2 string
err error
pvConfig1, pvConfig2 e2epv.PersistentVolumeConfig
pv1, pv2 *v1.PersistentVolume
pvSource1, pvSource2 *v1.PersistentVolumeSource
pvc1, pvc2 *v1.PersistentVolumeClaim
clientPod *v1.Pod
)
ginkgo.BeforeEach(func(ctx context.Context) {
e2eskipper.SkipUnlessProviderIs("gce")
e2eskipper.SkipUnlessSSHKeyPresent()
ginkgo.By("Initializing first PD with PVPVC binding")
pvSource1, diskName1 = createGCEVolume(ctx)
framework.ExpectNoError(err)
pvConfig1 = e2epv.PersistentVolumeConfig{
NamePrefix: "gce-",
Labels: volLabel,
PVSource: *pvSource1,
Prebind: nil,
}
pv1, pvc1, err = e2epv.CreatePVPVC(ctx, c, f.Timeouts, pvConfig1, pvcConfig, ns, false)
framework.ExpectNoError(err)
framework.ExpectNoError(e2epv.WaitOnPVandPVC(ctx, c, f.Timeouts, ns, pv1, pvc1))
ginkgo.By("Initializing second PD with PVPVC binding")
pvSource2, diskName2 = createGCEVolume(ctx)
framework.ExpectNoError(err)
pvConfig2 = e2epv.PersistentVolumeConfig{
NamePrefix: "gce-",
Labels: volLabel,
PVSource: *pvSource2,
Prebind: nil,
}
pv2, pvc2, err = e2epv.CreatePVPVC(ctx, c, f.Timeouts, pvConfig2, pvcConfig, ns, false)
framework.ExpectNoError(err)
framework.ExpectNoError(e2epv.WaitOnPVandPVC(ctx, c, f.Timeouts, ns, pv2, pvc2))
ginkgo.By("Attaching both PVC's to a single pod")
clientPod, err = e2epod.CreatePod(ctx, c, ns, nil, []*v1.PersistentVolumeClaim{pvc1, pvc2}, f.NamespacePodSecurityLevel, "")
framework.ExpectNoError(err)
})
ginkgo.AfterEach(func(ctx context.Context) {
// Delete client/user pod first
framework.ExpectNoError(e2epod.DeletePodWithWait(ctx, c, clientPod))
// Delete PV and PVCs
if errs := e2epv.PVPVCCleanup(ctx, c, ns, pv1, pvc1); len(errs) > 0 {
framework.Failf("AfterEach: Failed to delete PVC and/or PV. Errors: %v", utilerrors.NewAggregate(errs))
}
pv1, pvc1 = nil, nil
if errs := e2epv.PVPVCCleanup(ctx, c, ns, pv2, pvc2); len(errs) > 0 {
framework.Failf("AfterEach: Failed to delete PVC and/or PV. Errors: %v", utilerrors.NewAggregate(errs))
}
pv2, pvc2 = nil, nil
// Delete the actual disks
if diskName1 != "" {
framework.ExpectNoError(e2epv.DeletePDWithRetry(ctx, diskName1))
}
if diskName2 != "" {
framework.ExpectNoError(e2epv.DeletePDWithRetry(ctx, diskName2))
}
})
ginkgo.It("should delete a bound PVC from a clientPod, restart the kube-control-manager, and ensure the kube-controller-manager does not crash", func(ctx context.Context) {
e2eskipper.SkipUnlessSSHKeyPresent()
ginkgo.By("Deleting PVC for volume 2")
err = e2epv.DeletePersistentVolumeClaim(ctx, c, pvc2.Name, ns)
framework.ExpectNoError(err)
pvc2 = nil
ginkgo.By("Restarting the kube-controller-manager")
err = e2ekubesystem.RestartControllerManager(ctx)
framework.ExpectNoError(err)
err = e2ekubesystem.WaitForControllerManagerUp(ctx)
framework.ExpectNoError(err)
framework.Logf("kube-controller-manager restarted")
ginkgo.By("Observing the kube-controller-manager healthy for at least 2 minutes")
// Continue checking for 2 minutes to make sure kube-controller-manager is healthy
err = checkForControllerManagerHealthy(ctx, 2*time.Minute)
framework.ExpectNoError(err)
})
})
ginkgo.Context("when kubelet restarts", func() {
var (
clientPod *v1.Pod
@ -277,19 +154,6 @@ var _ = utils.SIGDescribe("NFSPersistentVolumes", framework.WithDisruptive(), fr
})
})
// createGCEVolume creates PersistentVolumeSource for GCEVolume.
func createGCEVolume(ctx context.Context) (*v1.PersistentVolumeSource, string) {
diskName, err := e2epv.CreatePDWithRetry(ctx)
framework.ExpectNoError(err)
return &v1.PersistentVolumeSource{
GCEPersistentDisk: &v1.GCEPersistentDiskVolumeSource{
PDName: diskName,
FSType: "ext3",
ReadOnly: false,
},
}, diskName
}
// initTestCase initializes spec resources (pv, pvc, and pod) and returns pointers to be consumed
// by the test.
func initTestCase(ctx context.Context, f *framework.Framework, c clientset.Interface, pvConfig e2epv.PersistentVolumeConfig, pvcConfig e2epv.PersistentVolumeClaimConfig, ns, nodeName string) (*v1.Pod, *v1.PersistentVolume, *v1.PersistentVolumeClaim) {